39

S

AFETY

D

EVICES

L

OCATION

F

UNCTION

C

OMPUTER

D

ISPLAY

M

ESSAGE

R

ESULT OF

T

RIPPING

L

OAD

D

OOR

S

WITCH

L

EFT

S

IDE

O

F

L

OAD

D

OOR

I

NSURES DRYER LOAD

DOOR ARE CLOSED

"DOOR

OPEN"

D

RYER WILL NOT RUN

U

NLOAD DOOR

SWITCH

(T

WO DOOR

UNIT ONLY

)

R

IGHT SIDE OF

UNLOAD DOOR

I

NSURES DRYER

UNLOAD DOORS ARE

CLOSED

"DOOR

OPEN"

D

RYER WILL NOT RUN

T

ILTING

S

WITCHES

T

OP LEFT SIDE OF

BASE MODULE

I

NSURES DRYER IS

LEVEL

"LEVEL

FAULT"

D

RYER WILL NOT RUN

D

RUM

R

OTATION

S

ENSOR

L

EFT SIDE OF

TUMBLER SECTION

I

NSURES TUMBLER IS

ROTATING

"DRUM

FAULT"

S

TOPS HEAT ONLY

L

INT

C

HAMBER AIR

PRESSURE SWITCH

C

ENTER OF HEAT

CONSOLE

I

NSURES PROPER AIR

FLOW THROUGH

DRYER

"AIRFLOW

FAULT"

S

TOPS HEAT ONLY

B

URNER

F

AN

A

IR

F

LOW

S

WITCH

(G

AS

D

RYERS

O

NLY

)

C

ENTER OF HEAT

CONSOLE

I

NSURES PROPER

CAOMBUSTION AIR

FLOW INTO THE

BURNER BOX

"HEATER

FAULT"

S

TOPS HEAT ONLY

H

I

/L

O

G

AS

P

RESSURE

S

WITCH

(G

AS

D

RYERS

O

NLY

)

L

OWER LEFT OF

HEAT CONSOLE

SECTION

I

NSURES PROPER GAS

SUPPLY PRESSURE FOR

ADEQUATE IGNITION

"GAS

SUPPLY

FAULT"

S

TOPS HEAT ONLY

H

EAT

R

ECLAIMER

D

AMPER

S

WITCH

R

IGHT SIDE OF HEAT

CONSOLE

I

NSURES THAT THE

HEAT RECLAIMER IS

EITHER OPENED OR

CLOSED

I

NPUT

LED

#13

OF

THE

PLC

IS OFF

N

ONE

H

EAT

C

ONSOLE

D

OOR

A

CCESS

D

OOR

S

WITCH

I

NSIDE

H

EAT

C

ONSOLE

I

NSURES THAT ACCESS

DOORS ARE CLOSED

"DOOR

OPEN"

D

RYER WILL NOT RUN

E

XHAUST

A

IR

T

EMP

C

ONTROL

S

ENSOR

I

NSIDE

B

URNER

SECTION DUCT

M

ONITORS TUMBLER

EXHAUST AIR TEMP

"EXHAUST

DSFL"

S

TOPS HEAT ONLY

E

XHAUST

A

IR

H

I

T

EMP

C

ONTROL

S

ENSOR

I

NSIDE EXHAUST

DUCT

M

ONITORS TUMBLER

EXHAUST AND AIR

TEMP

"HI-TEMP

FAULT"

S

TOPS HEAT ONLY

I

NTAKE

A

IR

T

EMP

C

ONTROL

S

ENSOR

(

OPTIONAL

)

T

OP RIGHT OF

TUMBLER SECTION

M

ONITORS TUMBLER

AIR INTAKE TEMP

"INTAKE

DSFL"

S

TOPS HEAT ONLY

I

NTAKE

A

IR

T

EMP

C

ONTROL

S

ENSOR

T

OP RIGHT OF

TUMBLER SECTION

M

ONITORS TUMBLER

AIR INTAKE TEMP

"HI-TEMP

FAULT"

S

TOPS HEAT ONLY

B

URNER

H

I

-L

IMIT

S

AFETY

S

ENSOR

T

OP OF BURNER

SECTION

M

ONITORS AIR TEMP

ABOVE THE BURNER

BOX

"HI-TEMP

FAULT"

S

TOPS HEAT ONLY

S

PRINKLER

C

ONTROL

S

AFETY

S

ENSOR

T

OP RIGHT OF

TUMBLER SECTION

O

PEN SPRINKLER

SYSTEM WATER VALVE

ON HI

-

TEMP

CONDITION

O

RANGE SPRINKLER

PILOT LIGHT COMES ON

.

A

LARM HORN SOUNDS

O

PENS THE SPRINKLER

WATER VALVE AND

POWER DOWN THE

WHOLE DRYER

L

INT

D

RAWER

S

WITCHES

A

BOVE LINT DRAWER

HANDLES

D

ISABLES MACHINE

WHEN DRAWERS ARE

OPEN OR IF DRAWERS

HAVE NOT BEEN

CLEANED IN LAST FIVE

LOADS

.

L

INT

D

RAWER

D

RYER WILL NOT RUN