beautypg.com

ALLIED Vision Technologies Pearleye P-030 LWIR User Manual

Page 60

background image

Advanced parameters and commands

Pearleye Technical Manual V2.3.0

60

Example

Set the factory default (115200 Baud and activate serial interface via Gigabit
Ethernet).

>s=2A[CR]

s 0

Operation Mode

Integrator / Image

Store

F

E

D

C

B

A

9

8

7

6

5

4

3

2

1

0

-

-

-

-

-

-

-

-

e

a

a

-

x

x

x

x

rw

rw rw

rw rw rw rw

Bit group

Value (hex)

Description

x

O

110 Baud

1

300 Baud

2

600 Baud

3

1200 Baud

4

2400 Baud

5

4800 Baud

6

9600 Baud

7

19200 Baud

8

38400 Baud

9

57600 Baud

A

115200 Baud

a

00

RS232 via 15 pin SUB-D only.

01

Additionally activate second channel via Pleora device port serial 0.

10

Additionally activate second channel vis Pleora device port bulk 0
(MODE:UART).

11

Reserved.

e

0

Each character received from the host is echoed back to it.

1

No Echo.

Table 31: Baud rates: values