Specifications

Pearleye Technical Manual V2.3.0

13

Specifications

Pearleye P-007 LWIR / P-007 LWIR High Temp

Note

The warranty becomes void in case of unauthorized tampering
or any modifications not approved by Allied Vision Technolo-
gies.

Caution

Surge

To avoid damage caused by surge, connect the camera to an
AC/DC power supply. Use a certified industrial power supply
that complies with common industrial standards. Make sure
the polarization of the power supply is correct.

During the camera start-up, inrush currents ≥ 4 A can occur for
20 ms. Use a sufficiently dimensioned power supply to avoid
damage to the camera.

For the DC signal, use cable lengths less than 30 m. Consider
that the voltage drop increases with the cable length.

AVT (or your local dealer) provides suitable power supplies:

http://www.alliedvisiontec.com/emea/products/
accessories.html

Feature

Specification

Sensor

Amorphous silicon uncooled microbolometer focal plane array (FPA)
ULIS UL 03 08 1; built-in electromechanical shutter

Effective chip size

11.2 mm (H) x 8.4 mm (V)

Cell size

35 μm x 35 μm

Resolution (max.)

320 (H) x 240 (V)

Lens mount

M65 x 0.5

Field of view (FOV)

With 18 mm lens: 35° x 26°

Focus range

0.5 m to

manually adjustable)

Spectral response

8 μm to 14 μm (LWIR)

Pixel format

Mono12

Frame rate

up to 40 fps

Table 3: Specification Pearleye P-007 LWIR / P-007 LWIR High Temp