Specifications, Pearleye p-007 lwir / p-007 lwir high temp, Ons chapter – ALLIED Vision Technologies Pearleye P-030 LWIR User Manual
Page 13: Nge in chapter, Pearleye p-007 lwir / p-007, Lwir high temp, Chapter, In chapter, Pearleye p, 007 lwir / p-007 lwir high temp
Specifications
Pearleye Technical Manual V2.3.0
13
Specifications
Pearleye P-007 LWIR / P-007 LWIR High Temp
Note
The warranty becomes void in case of unauthorized tampering
or any modifications not approved by Allied Vision Technolo-
gies.
Caution
Surge
To avoid damage caused by surge, connect the camera to an
AC/DC power supply. Use a certified industrial power supply
that complies with common industrial standards. Make sure
the polarization of the power supply is correct.
During the camera start-up, inrush currents ≥ 4 A can occur for
20 ms. Use a sufficiently dimensioned power supply to avoid
damage to the camera.
For the DC signal, use cable lengths less than 30 m. Consider
that the voltage drop increases with the cable length.
AVT (or your local dealer) provides suitable power supplies:
accessories.html
Feature
Specification
Sensor
Amorphous silicon uncooled microbolometer focal plane array (FPA)
ULIS UL 03 08 1; built-in electromechanical shutter
Effective chip size
11.2 mm (H) x 8.4 mm (V)
Cell size
35 μm x 35 μm
Resolution (max.)
320 (H) x 240 (V)
Lens mount
M65 x 0.5
Field of view (FOV)
With 18 mm lens: 35° x 26°
Focus range
0.5 m to
manually adjustable)
Spectral response
8 μm to 14 μm (LWIR)
Pixel format
Mono12
Frame rate
up to 40 fps
Table 3: Specification Pearleye P-007 LWIR / P-007 LWIR High Temp