MoTeC PLM User Manual
Page 50
50
Appendices
Message 4
Byte
Name
Scaling
0
Compound ID – user defined,
default 3
N/A
1
Positive Analog output pin
voltage
Byte*1000/255–500 = x.xx V
2
Negative Analog output pin
voltage
Byte*1000/255–500 = x.xx V
3
Sensor type
NONE
NTK
BOSCH LSU4
BOSHC LSU4.2
0
1
2
3
4
Reset source (Note 2)
Low Voltage reset
Illegal Address reset
Illegal operation reset
Watchdog timer reset
External reset
2
8
16
32
64
5
Firmware Version
x.xx
6:7
RPM HI:LO
xxxxx RPM
Message 5
Byte
Name
Scaling
0
Compound ID = 4
N/A
1
Reserved
N/A
2:3
PLM 1 (Master PLM) Calibrated Sensor Output
Value
Hi:Lo*1 = x.xxxLa
(Note 1)
4:5
PLM 2 Calibrated Sensor Output Value
Hi:Lo*1 = x.xxxLa
(Note 1)
6:7
PLM 3 Calibrated Sensor Output Value
Hi:Lo*1 = x.xxxLa
(Note 1)
Message 6
Byte
Name
Scaling
0
Compound ID = 5
N/A
1
Reserved
N/A
2:3
PLM 4 Calibrated Sensor Output Value
Hi:Lo*1 = x.xxxLa
(Note 1)
4:5
PLM 5 Calibrated Sensor Output Value
Hi:Lo*1 = x.xxxLa
(Note 1)
6:7
PLM 6 Calibrated Sensor Output Value
Hi:Lo*1 = x.xxxLa
(Note 1)