PLM Communications

25

The base address is the address on which the collected Lambda values will be
retransmitted. This address must lie on a 16 message boundary (i.e. the
address, in hex, must end in 0). The base address also defined the addresses
of the Collect slave units that the master will monitor. The recommended
address is Hex 460.

The message rate is the rate at which the Lambda values are retransmitted on
the CAN bus to the measuring device (usually an ADL or ECU).

Messages 1 to 4 do not need to be configured on the master unit.

Output to Transmit must be LA V1, with 3 decimal places in the table setup.

The master PLM unit will briefly display “CU 1” (Collect Unit 1) on start-up after
displaying the firmware version.

If the slave PLM stops transmitting to the master PLM for 1.5 seconds then the
master PLM will retransmit a value of 0 for the missing slave.

Configuring the CAN Collect slave units (PLM 2
to PLM 16)

The Message 1 tab of the CAN Message Setup dialog must be configured as
follows:

Output To Transmit

LA V1, with 3 decimal places in the table

Address Format

Standard

Compound ID

00

Message Rate

As required for application. This is the rate at which the
Lambda value for this unit will be sent to the master
unit.

Address

Master PLM Collect Master Base Address + PLM
number – 1 (in hexadecimal)

Eg. For a master PLM base address Hex 460:

PLM 5 address would be Hex 464

PLM 12 address would be Hex 46B