Appendix b: sensor supplies – MoTeC M880 User Manual
Page 80

78 Appendices
Appendix B: Sensor Supplies
Maximum Current
5V ENG Sensor Supply: 0.20 Amps Max
5V AUX Sensor Supply: 0.15 Amps Max
8V ENG Sensor Supply: 0.30 Amps Max
8V AUX Sensor Supply: 0.30 Amps Max
Accuracy / Temp Drift
5V ENG Sensor Supply:
± 0.5% max at 25°C + 100ppm/°C max
5V AUX Sensor Supply:
± 0.5% max at 25°C + 100ppm/°C max
8V ENG Sensor Supply:
± 5% max over entire temperature range
8V AUX Sensor Supply:
± 5% max over entire temperature range
Protection
Short to ground
Short to battery
Thermal overload