4080 series Function & Arbitrary/Function Generators –Instruction Manual

45

Check the sweep time.

SWEep:SOURce {INTernal|EXTernal}
Set trigger source of sweep as internal (INTernal) or external (EXTernal).

SWEep:SOURce?
Check current trigger source.

SWEep:STATe {ON|OFF}
Turn on sweep mode (ON) or turn off sweep mode (OFF).

SWEep:STATe?
Check the “on/off” state of sweep mode. The returned data are “0” (OFF) or “1” (ON). It returns to
fixed frequency mode in “off” state.

Counting instructions
FUNCtion:TOTal INITial
Initialize the counter.

FUNCtion:TOTal STARt
Set the counter to start counting.

FUNCtion:TOTal STOP
Set the counter to stop counting.

FUNCtion:TOTal CLEAr
Clear the counted value of the counter.

FUNCtion:TOTal?
Record the current value of the counter.

Frequency Measurement instructions
FUNCtion:FREQuency MEASure
Enable frequency measurement function for the instrument to start a new frequency measurement.

FUNCtion:FREQuency?
Record last frequency value after frequency measurement is finished.

FUNCtion:FREQuency GATE

System related instructions:

*IDN?
This query will return the instrument’s manufacturer, model number and firmware version.
Example: B+K Precision 4084AWG V1.00