Channel filters (analyzer mode)
Bandwidths (–3 dB)

standard
(RRC = root raised cosine)

100/200/300/500 Hz
1/1.5/2/2.4/2.7/3/3.4/4/4.5/5/6/8.5/9/10/
12.5/14/15/16/18 (RRC)/20/21/24.3 (RRC)
/25/30/50/100/150/192/200/300/500 kHz
1/1.228/1.28 (RRC)/1.5/2/3/3.84 (RRC)/
4.096 (RRC)/5/10/20/28/40 MHz

Bandwidth accuracy

< 2 % (nom.)

Shape factor 60 dB:3 dB

< 2 (nom.)

Video bandwidths (analyzer mode)

1 Hz to 10 MHz in 1/2/3/5 sequence,
20 MHz, 28 MHz, 40 MHz

Level

Display range

displayed noise floor up to +130 dBm

Max. input level

AC coupled

50 V

DC coupled

0 V

CW RF power

RF attenuation = 0 dB
RF preamplifier = off

20 dBm (= 0.1 W)

RF preamplifier = on

13 dBm (= 0.02 W)

RF attenuation ≥ 10 dB
RF preamplifier = off

30 dBm (= 1 W)

RF preamplifier = on

23 dBm (= 0.2 W)

Pulse spectral density

RF attenuation ≥ 0 dB, preselection = on

4

,

RF preamplifier = off

97 dB µV/MHz

Max. pulse voltage

RF attenuation ≥ 10 dB

150 V

Max. pulse energy

RF attenuation ≥ 10 dB, 10 µs

1 mWs

Intermodulation
1 dB compression of input mixer

RF attenuation = 0 dB, preselection and
preamplifier = off

5

+3 dBm (nom.)

Third-order intercept point (TOI)

RF attenuation = 0 dB, level = 2 × –15 dBm, ∆f > 5 × RBW or 10 kHz, whichever is
larger, preselection = off

5

, with R&S

®

FSV-B22 option: RF preamplifier = off

10 MHz ≤ f

in

< 100 MHz

> 12 dBm, 15 dBm typ.

100 MHz ≤ f

in

< 3.6 GHz

> 13 dBm, 16 dBm typ.

3.6 GHz ≤ f

in

≤ 7 GHz

> 15 dBm, 18 dBm typ.

with R&S

®

ESRP-B2 option,

preselection = on

6

, preamplifier = off, RF attenuation = 0 dB, level = 2 × –20 dBm,

∆f > 5 × RBW or 10 kHz, whichever is larger

10 MHz ≤ f

in

< 100 MHz

> 5 dBm, 8 dBm typ.

100 MHz ≤ f

in

< 4.5 GHz

> 8 dBm, 11 dBm typ.

4.5 GHz ≤ f

in

≤ 7 GHz

> 5 dBm, 8 dBm typ.

with R&S

®

ESRP-B2 option,

preselection = on

6

, preamplifier = on, RF attenuation = 0 dB, level = 2 × –45 dBm,

∆f > 5 × RBW or 10 kHz, whichever is larger

10 MHz ≤ f

in

< 100 MHz

> –16 dBm,–13 dBm typ.

100 MHz ≤ f

in

< 3.6 GHz

> –14 dBm,–11 dBm typ.

3.6 GHz ≤ f

in

≤ 7 GHz

> –10 dBm,–7 dBm typ.

with R&S

®

FSV-B22 option,

preselection = off

5

, RF preamplifier = on, RF attenuation = 0 dB, level = 2 × –45 dBm,

∆f > 5 × RBW or 10 kHz, whichever is larger

10 MHz ≤ f

in

< 100 MHz

–3 dBm (nom.)

100 MHz ≤ f

in

< 3.6 GHz

–2 dBm (nom.)

3.6 GHz ≤ f

in

≤ 7 GHz

0 dBm (nom.)

4

With R&S

®

ESRP-B2 option.

5

With R&S

®

ESRP-B2 option. Preselection = off is only available in analyzer mode. In receiver mode the preselection is permanently on.