Specifications, Frequency – Atec Rohde-Schwarz-ESRP Series User Manual
Page 4
Version 01.01, January 2013
4
Rohde & Schwarz R&S
®
ESRP EMI Test Receiver
Specifications
Operating modes
EMI test receiver
spectrum analyzer
Frequency
Frequency range
R&S
®
ESRP3
AC coupled
10 MHz to 3.6 GHz
DC coupled
9 kHz to 3.6 GHz
R&S
®
ESRP7
AC coupled
10 MHz to 7 GHz
DC coupled
9 kHz to 7 GHz
with R&S
®
ESRP-B29 option, DC coupled
10 Hz to max. frequency
Frequency resolution
receiver mode
0.1 Hz
analyzer mode
0.01 Hz
Reference frequency, internal
Accuracy
±((time since last adjustment × aging rate)
+ temperature drift + calibration accuracy)
Aging per year
standard
±1 × 10
–6
with R&S
®
FSV-B4 option
±1 × 10
–7
Temperature drift (+5 °C to +45 °C)
standard
±1 × 10
–6
with R&S
®
FSV-B4 option, model .02
±1 × 10
–7
with R&S
®
FSV-B4 option, model .03
±1 × 10
–8
Max. initial calibration accuracy
standard
±5 × 10
–7
with R&S
®
FSV-B4 option
±5 × 10
–8
Frequency readout (analyzer mode)
Marker resolution
1 Hz
Uncertainty
±(marker frequency × reference accuracy
+ 10 % × resolution bandwidth +
½ (span/(sweep points – 1)) + 1 Hz)
Number of sweep (trace) points
default value
691
range
spectrum analyzer
101 to 32 001
EMI measurement
101 to 200 001
Marker tuning frequency step size
marker step size = sweep points
span/(sweep points – 1)
marker step size = standard
span/(default sweep points – 1)
Frequency counter resolution
0.001 Hz
Count accuracy
±(frequency × reference accuracy +
½ (last digit))
Display range for frequency axis
0 Hz, 10 Hz to max. frequency
Resolution
0.1
Hz
Max. span deviation
±0.1 %
Receiver scan
Scan
scan with max. 10 subranges with different
settings
Scan modes
normal scan, time domain scan
1
Measurement time
normal scan, per frequency
50 µs to 100 s
time domain scan, per subrange
1
50 µs to 100 s
Number of trace points
up to 4 000 000
Frequency step size
normal scan
min. 1 Hz
time domain scan
1
0.25 × resolution bandwidth
Time domain scan
1
Frequency segment processed in parallel
RBW = 200 Hz
0.66 MHz
RBW = 9 kHz
30 MHz
RBW = 120 kHz
24.6 MHz
RBW = 1 MHz
25.6 MHz
FFT overlap factor
≥ 93 %
1
Requires R&S
®
ESRP-K53 option.