beautypg.com

Mentor 12 – Atec EuroSMC-Mentor-12 User Manual

Page 4

background image

MENTOR 12

Low Level Outputs, USB and Ethernet connections

4

POWER

A state-of-the-art, fully programmable digital waveform generation engine constitutes the heart of the

Mentor 12. It is able to control twelve independent low-level signal paths to the output section,

producing extremely accurate signals with a 3-kHz bandwidth. These signals are driven to the output

amplifiers for a stable, distortion-free 100 VA testing power. Prior to being amplified, these signals are

also available at the low-level output connectors to test and calibrate transducers, energy meters and

sensor- or Rogowski coil-based protective relays, as well as to be externally amplified for applications

that require greater current or voltage limits.

The output amplifiers of the Mentor 12 deliver a stable and efficient output, with a power curve adapted

to the most demanding test conditions. The unit can be charged with up to 6 current and 6 voltage

amplifiers, each of which supply top-quality 100 VA/W permanent power simultaneously. The resulting

1,200 VA power allows for the complete three-phase testing of two relays at the same time, including

the logical scheme and messaging functions, simulated and recorded by the 8 binary outputs and 12

inputs available in the Mentor 12.

FLEXIBILITY

You might not need twelve channels right now. Start with a

smaller configuration and add more channels when you

need them. The Mentor 12’s amplifiers are plug and play.

You just remove the unit’s side cover, slide the

amplifier(s) in, turn the unit on and continue working.

The new amplifiers will be recognized and added to all

the test and configuration screens by the Mentor 12

automatically.

POWER OUTPUTS CONFIGURATION

Regardless the number of amplifiers in your Mentor 12, you can also combine them in series and in

parallel to attain greater voltage and current levels. The output configuration screen displays a menu

with all the possible combinations and a visual guide to help you at connecting the relay. There is no

need to calculate partial current, voltage or phase angle values as the Mentor 12 manages and shows

each group of combined channels as if it were a single “virtual “one.

Furthermore, each voltage amplifier can be switched to current mode by a simple touch on the

configuration screen. This feature allows, for example, to convert a Mentor 12 3v3i (3 voltage + 3 current

channels) to a six-current test set when the need for testing three-phase differential relay arises.

Low Level Outputs and superimposed harmonics for every source can also be activated in this control.

You can accurately measure the output from a transducer, an energy meter or any other measurement device

by connecting it to the analogue or binary inputs while injecting known quantities with the Mentor 12.

PRODUCTIVITY

The Mentor 12’s human interface is organized to complete the job safely and accurately in the

shortest possible time. Locating the necessary controls and the relevant test information will take just

a few seconds to the untrained expert. The Basic Control panel has been designed especially for him.

Adjusting a few values and testing a handful of trip points in the relay is a snap, thanks to the touch-

sensitive panel and the rotary knob. There is no need to even look at the relay, as its response is displayed

on the control screen in real time.

The Mentor 12 includes the transient fault Playback as standard. You only need to copy your COMTRADE

files into a USB pendrive, plug it into the unit and press Playback. If you want, you can assign each

current and voltage signal in the recording to specific current and voltage channels for the playback.

You can map the recorded binary information and the response of the relay to any of the binary outputs

and inputs in the Mentor 12. You can also discard the unneeded signal’s sections or adjust the best

transformation ratio for the playback. Press Playback to examine the streamed signals and the relay’s

reactions in the screen.

Combining two voltage channels in series

COMTRADE transient playback