Digital generator (option upl-b2 or -b29) – Atec Rohde-Schwarz-UPL User Manual
Page 19
![background image](/manuals/318893/19/background.png)
Audio Analyzer UPL
19
Frequency setting
– automatic to input signal
– coupled to generator
– fixed through entered value
– sweep in selectable range
Accuracy
±
0.2 dB + ripple of filters
Peak value
Measurement
peak max, peak min, peak-to-peak,
peak absolute
Accuracy
±
0.2 dB at 1 kHz
Interval
20 ms to 10 s
Filter
1)
weighting filters and user-definable fil-
ters, up to 3 filters can be combined
Quasi-peak
Measurement, accuracy
to CCIR 468-4
Filter
1)
weighting filters and user-definable fil-
ters, up to 3 filters can be combined
DC voltage
Measurement range
0 to
±
FS
Accuracy
±
1%
S/N measurement routine
available for measurement functions:
– rms, wideband
– peak
– quasi-peak
indication of S/N ratio in dB,
no post-FFT
FFT analysis
see FFT analyzer section
Total harmonic distortion (THD)
Fundamental
10 Hz to 21.90 kHz
Frequency tuning
automatic to input or generator signal
or fixed through entered value
Weighted harmonics
any combination of d
2
to d
9,
up to 21.90 kHz
Accuracy
±
0.1 dB
Inherent distortion
2)
Fundamental 42 Hz to 21.90 kHz
<
–130 dB
24 Hz to 42 Hz
<
–112 dB
12 Hz to 24 Hz
<
–88 dB
Spectrum
bar chart showing signal and distortion
THD+N and SINAD
Fundamental
10 Hz to 21.90 kHz
Frequency tuning
automatic to input or generator signal
or fixed through entered value
Stopband range
fundamental
±
28 Hz,
max. up to 2nd harmonic
Bandwidth
upper and lower frequency limit se-
lectable, one weighting filter in addi-
tion
Accuracy
±
0.3 dB
Inherent distortion
2)
Bandwidth
20 Hz to 21.90 kHz
Fundamental 28 Hz to 21.90 kHz
<
–126 dB
24 Hz to 28 Hz
<
–109 dB
20 Hz to 24 Hz
<
–96 dB
Spectrum
post-FFT of filtered signal
Modulation factor (MOD DIST)
Measurement method
selective to DIN IEC 268-3
Frequency range
Lower frequency
30 Hz to 2700 Hz
3)
Upper frequency
8 x LF
3)
to 21.25 kHz
Accuracy
±
0.2 dB
Inherent distortion
2)
Level LF:UF
1:1
<
–133 dB
4:1
<
–123 dB
10:1
<
–115 dB
Spectrum
bar chart showing signal and distortion
Difference frequency distortion (DFD)
Measurement method
selective to DIN IEC 268-3 or 118
Frequency range
Difference frequency
80 Hz to 2 kHz
3)
Center frequency
200 Hz to 20.90 kHz
Accuracy
±
0.2 dB
Inherent distortion
2)
DFD d
2
<
–130 dB
DFD d
3
<
–130 dB
Spectrum
bar chart showing signal and distortion
1)
With UPL-B29 only in base rate mode.
2)
Total inherent distortion of analyzer and generator.
3)
Fixed frequency, independent of sampling rate.
Wow and flutter
Measurement method
DIN/IEC, NAB, JIS,
2-sigma to IEC-386
Weighting filter OFF
highpass 0.5 Hz, bandwidth 200 Hz
ON
bandpass 4 Hz to IEC-386
Accuracy
±
3%
Inherent noise
<
0.0003% weighted
<
0.0008% unweighted
Spectrum
post-FFT of demodulated signal
Time domain display (WAVEFORM)
Trigger
rising/falling edge
Trigger level
–1 FS to +1 FS, interpolated between
samples
Trace length
max. 7424 points
Standard mode
1- to 32-fold interpolation
Compressed mode
32- to 1024-fold compression
(envelope for AGC measurement)
Frequency
4)
Frequency range
20 Hz to 20 kHz
Accuracy
±
50 ppm
Phase
4)
Frequency range
20 Hz to 20 kHz
Accuracy
±
0.5°
Group delay
4)
Frequency range
20 Hz to 20 kHz
Accuracy in seconds
∆ϕ
/
(∆
f x 360), where
∆ϕ
= phase
accuracy in °,
∆
f = frequency step
Polarity test
Measurement
polarity of unsymmetrical input signal
Display
+POL, –POL
Digital generator (option UPL-B2 or -B29)
Frequency limits specified for the signals apply to a sampling rate of 48 kHz.
For other sampling rates limits are calculated according to the formula:
f
new
= f
48 kHz
x sampling rate/48 kHz.
Outputs
Balanced output
XLR connector, transformer coupling
Impedance
110
Ω
, short-circuit-proof
Level (V
PP
into 110
Ω
)
0 V to 8 V, in 240 steps
Accuracy
±
1 dB (rms)
Unbalanced output
BNC, transformer coupling
Impedance
75
Ω
, short-circuit-proof
Level (V
PP
into 75
Ω)
0 V to 2 V, in 240 steps
Accuracy
±
1 dB (rms)
Optical output
TOSLINK
Channels
1, 2 or both
Audio bits
8 to 24
Clock rate
35 kHz to 55 kHz with UPL-B2 or
UPL-B29 in base rate mode
35 kHz to 106 kHz with UPL-B29 in
high rate mode
internal: generator clock or synchroni-
zation to analyzer
external: synchronization to word clock
input, video sync, DARS, 1024 kHz
Format
professional and consumer format to
AES3 or IEC-958 as well as user-
definable formats at all outputs
4)
Only for measurement functions RMS, FFT and THD+N, accuracy applies to
8k FFT with zoom factor 2, Rife-Vincent-2 window; S/N ratio >70 dB.
Phase and group delay in high rate mode only with RMS without filter.