19

Frequency setting

– automatic to input signal
– coupled to generator
– fixed through entered value
– sweep in selectable range

Accuracy

±

0.2 dB + ripple of filters

Peak value
Measurement

peak max, peak min, peak-to-peak,
peak absolute

Accuracy

±

0.2 dB at 1 kHz

Interval

20 ms to 10 s

Filter

1)

weighting filters and user-definable fil-
ters, up to 3 filters can be combined

Quasi-peak
Measurement, accuracy

to CCIR 468-4

Filter

1)

weighting filters and user-definable fil-
ters, up to 3 filters can be combined

DC voltage
Measurement range

0 to

±

FS

Accuracy

±

1%

S/N measurement routine

available for measurement functions:
– rms, wideband
– peak
– quasi-peak
indication of S/N ratio in dB,
no post-FFT

FFT analysis

see FFT analyzer section

Total harmonic distortion (THD)
Fundamental

10 Hz to 21.90 kHz

Frequency tuning

automatic to input or generator signal
or fixed through entered value

Weighted harmonics

any combination of d

2

to d

9,

up to 21.90 kHz

Accuracy

±

0.1 dB

Inherent distortion

2)

Fundamental 42 Hz to 21.90 kHz

<

–130 dB

24 Hz to 42 Hz

<

–112 dB

12 Hz to 24 Hz

<

–88 dB

Spectrum

bar chart showing signal and distortion

THD+N and SINAD
Fundamental

10 Hz to 21.90 kHz

Frequency tuning

automatic to input or generator signal
or fixed through entered value

Stopband range

fundamental

±

28 Hz,

max. up to 2nd harmonic

Bandwidth

upper and lower frequency limit se-
lectable, one weighting filter in addi-
tion

Accuracy

±

0.3 dB

Inherent distortion

2)

Bandwidth

20 Hz to 21.90 kHz

Fundamental 28 Hz to 21.90 kHz

<

–126 dB

24 Hz to 28 Hz

<

–109 dB

20 Hz to 24 Hz

<

–96 dB

Spectrum

post-FFT of filtered signal

Modulation factor (MOD DIST)
Measurement method

selective to DIN IEC 268-3

Frequency range

Lower frequency

30 Hz to 2700 Hz

3)

Upper frequency

8 x LF

3)

to 21.25 kHz

Accuracy

±

0.2 dB

Inherent distortion

2)

Level LF:UF

1:1

<

–133 dB

4:1

<

–123 dB

10:1

<

–115 dB

Spectrum

bar chart showing signal and distortion

Difference frequency distortion (DFD)
Measurement method

selective to DIN IEC 268-3 or 118

Frequency range

Difference frequency

80 Hz to 2 kHz

3)

Center frequency

200 Hz to 20.90 kHz

Accuracy

±

0.2 dB

Inherent distortion

2)

DFD d

2

<

–130 dB

DFD d

3

<

–130 dB

Spectrum

bar chart showing signal and distortion

1)

With UPL-B29 only in base rate mode.

2)

Total inherent distortion of analyzer and generator.

3)

Fixed frequency, independent of sampling rate.

Wow and flutter
Measurement method

DIN/IEC, NAB, JIS,
2-sigma to IEC-386

Weighting filter OFF

highpass 0.5 Hz, bandwidth 200 Hz

ON

bandpass 4 Hz to IEC-386

Accuracy

±

3%

Inherent noise

<

0.0003% weighted

<

0.0008% unweighted

Spectrum

post-FFT of demodulated signal

Time domain display (WAVEFORM)
Trigger

rising/falling edge

Trigger level

–1 FS to +1 FS, interpolated between
samples

Trace length

max. 7424 points

Standard mode

1- to 32-fold interpolation

Compressed mode

32- to 1024-fold compression
(envelope for AGC measurement)

Frequency

4)

Frequency range

20 Hz to 20 kHz

Accuracy

±

50 ppm

Phase

4)

Frequency range

20 Hz to 20 kHz

Accuracy

±

0.5°

Group delay

4)

Frequency range

20 Hz to 20 kHz

Accuracy in seconds

∆ϕ

/

(∆

f x 360), where

∆ϕ

= phase

accuracy in °,

f = frequency step

Polarity test
Measurement

polarity of unsymmetrical input signal

Display

+POL, –POL

Digital generator (option UPL-B2 or -B29)

Frequency limits specified for the signals apply to a sampling rate of 48 kHz.
For other sampling rates limits are calculated according to the formula:
f

new

= f

48 kHz

x sampling rate/48 kHz.

Outputs

Balanced output

XLR connector, transformer coupling

Impedance

110

, short-circuit-proof

Level (V

PP

into 110

)

0 V to 8 V, in 240 steps

Accuracy

±

1 dB (rms)

Unbalanced output

BNC, transformer coupling

Impedance

75

, short-circuit-proof

Level (V

PP

into 75

Ω)

0 V to 2 V, in 240 steps

Accuracy

±

1 dB (rms)

Optical output

TOSLINK

Channels

1, 2 or both

Audio bits

8 to 24

Clock rate

35 kHz to 55 kHz with UPL-B2 or
UPL-B29 in base rate mode
35 kHz to 106 kHz with UPL-B29 in
high rate mode
internal: generator clock or synchroni-
zation to analyzer
external: synchronization to word clock
input, video sync, DARS, 1024 kHz

Format

professional and consumer format to
AES3 or IEC-958 as well as user-
definable formats at all outputs

4)

Only for measurement functions RMS, FFT and THD+N, accuracy applies to
8k FFT with zoom factor 2, Rife-Vincent-2 window; S/N ratio >70 dB.
Phase and group delay in high rate mode only with RMS without filter.