General specifications – Atec Agilent-N5181B-N5182B User Manual
Page 29

29
General Specifications
Remote programming
Interfaces
GPIB IEEE-488 .2, 1987 with listen and talk
LAN 1000BaseT LAN interface, LXI class C compliant
USB Version 2 .0
Control languages
Control languages SCPI Version 1997 .0
Compatibility languages
Agilent Technologies: N5181A\61A, N 5182A\62A, N5183A, E4438C, E4428C, E442xB,
E443xB, E8241A, E8244A, E8251A, E8254A, E8247C, E8257C/D, E8267C/D, 8648 Series,
8656B, E8663B, 8657A/B, 8662A, 8663A
Aeroflex Incorporated: 3410 Series
Rohde & Schwarz: SMB100A, SMBV100A, SMU200A, SMJ100A, SMATE200A, SMIQ,
SML, SMV
Power requirements
100-120 VAC, 50/60/400 Hz
220-240 VAC, 50/60 Hz
160 W maximum (N5181B)
300 W maximum (N5182B)
Operating temperature range
0 to 55 °C
Storage temperature range
–40 to 70 °C
Operating and storage altitude
Up to 15,000 feet
Humidity
Relative humidity - type tested at 95%, +40 °C (non-condensing)
Environmental stress
Samples of this product have been type tested in accordance with the Agilent Environmental Test Manual and verified to be robust
against the environmental stresses of storage, transportation and end-use; those stresses include but are not limited to temperature,
humidity, shock, vibration, altitude, and power line conditions; test methods are aligned with IEC 60068-2 and levels are similar to MIL-
PRF-28800F Class 3
Safety
Complies with European Low Voltage Directive 2006/95/EC
• IEC/EN 61010-1, 2nd Edition
• Canada: CSA C22.2 No. 61010-1
• USA: UL std no. 61010-1, 2nd Edition
• German Acoustic statement
Acoustic noise emission
LpA < 70 dB
Operator position
Normal position
Per ISO 7779
Geraeuschemission
LpA < 70 dB
Am Arbeitsplatz
Normaler Betrieb
Nach DIN 45635 t .19
Complies with European EMC Directive 2004/108/EC
• IEC/EN 61326-1or IEC/EN 61326-2-1
• CISPR Pub 11 Group 1, class A
• AS/NZS CISPR 11
• ICES/NMB-001
This ISM device complies with Canadian ICES-001;
cet appareil ISM est conforme a la norme NMB-001 du Canada
Memory
• Memory is shared by instrument states, user data files, sweep list files, waveform sequences, and other files
• 3 GB (30 GB with Option 009) memory available in the N5182B
• Security Option 006 allows storage of up to 8 GB on SD card
• Depending on how the memory is utilized, a maximum of 1000 instrument states can be saved