Continued), Maximum swr and power linearity, Model frequency range maximum swr power linearity – Atec Agilent-EPM Series User Manual
Page 21
21
848xD Series Diode and 8483A Thermocouple Power Sensor Specifications
(continued)
Maximum SWR and power linearity
Table 14. 8480 Series maximum SWR and power linearity
Model
Frequency
range
Maximum
SWR
Power
linearity
1
Maximum
power
Connector
type
Weight
100 mW sensors, 1 μW to 100 mW (–30 dBm to +20 dBm)
8483A
(75-Ohm)
100 kHz to
2 GHz
100 kHz to 600 kHz: 1.80
600 kHz to 2 GHz: 1.18
+10 dBm to
+20 dBm: (±3%)
300 mW avg,
10 W pk
Type-N (m)
75 Ohm
Net:
0.2 kg (0.38 lb)
Shipping:
0.5 kg (1.0 lb)
V8486A
50 GHz to
75 GHz
50 GHz to 75 GHz: 1.06
–30 dBm to
+10 dBm: (±1%)
+10 dBm to
+20 dBm: (±2%)
200 mW avg,
40 W pk
(10.μs per pulse,
0.5% duty cycle)
Waveguide flange
UG-385/U
Net:
0.4 kg (0.9 lb)
Shipping:
1 kg (2.1 lb)
W8486A
75 GHz to
110 GHz
75 GHz to 110 GHz: 1.08
(±2%)
200 mW avg,
40 W pk
(10.μs per pulse,
0.5% duty cycle)
Waveguide flange
UG-387/U
Net:
0.4 kg (0.9 lb)
Shipping:
1 kg (2.1 lb)
High sensitivity sensors, 100 pW to 10 μW (–70 dBm to –20 dBm)
8481D
2
10 MHz to
18 GHz
10 MHz to 30 MHz: 1.40
30 MHz to 4 GHz: 1.15
4 GHz to 10 GHz: 1.20
10 GHz to 15 GHz: 1.30
15 GHz to 18 GHz: 1.35
–30 dBm to
–20 dBm: (±1%)
100 mW avg,
100 mW pk
Type-N (m)
Net:
0.16 kg (0.37 lb)
Shipping:
0.9 kg (2.0 lb)
8485D
2
50 MHz to
26.5 GHz
0.05 GHz to 0.1 GHz: 1.19
0.1 GHz to 4 GHz: 1.15
4 GHz to 12 GHz: 1.19
12 GHz to 18 GHz: 1.25
18 GHz to 26.5 GHz: 1.29
–30 dBm to
–20 dBm: (±2%)
100 mW avg,
100 mW pk
APC-3.5 mm (m)
Net:
0.2 kg (.38 lb)
Shipping:
0.5 kg (1.0 lb)
Option
8485D-033
50 MHz to
33 GHz
26.5 GHz to 33 GHz: 1.35
–30 dBm to
–20 dBm: (±2%)
100 mW avg,
100 mW pk
APC-3.5 mm (m)
Net:
0.2 kg (0.38 lb)
Shipping:
0.5 kg (1.0 lb)
8487D
2
50 MHz to
50 GHz
0.05 GHz to 0.1 GHz: 1.19
0.1 GHz to 2 GHz: 1.15
2 GHz to 12.4 GHz: 1.20
12.4 GHz to 18 GHz: 1.29
18 GHz to 34 GHz: 1.37
34 GHz to 40 GHz: 1.61
40 GHz to 50 GHz: 1.89
–30 dBm to
–20 dBm: (±2%)
100 mW avg,
100 mW pk
10 W.μs per
pulse
2.4 mm (m)
Net:
0.2 kg (0.38 lb)
Shipping:
0.5 kg (1.0 lb)
R8486D
2
26.5 GHz to
40 GHz
26.5 GHz to 40 GHz: 1.40
–30 dBm to
–25 dBm: (±3%)
–25 dBm to
–20 dBm: (±5%)
100 mW avg,
or pk 40 V
dc max
Waveguide flange
UG-599/U
Net:
0.26 kg (0.53 lb)
Shipping:
0.66 kg (1.3 lb)
Q8486D
2
33 GHz to
50 GHz
33 GHz to 50 GHz: 1.40
–30 dBm to
–25 dBm: (±3%)
–25 dBm to
–20 dBm: (±5%)
100 mW avg,
or pk 40 V
dc max
Waveguide flange
UG-383/U
Net:
0.26 kg (0.53 lb)
Shipping:
0.66 kg (1.3 lb)
1. Negligible deviation except for those power ranges noted.
2. Includes 11708A 30 dB attenuator for calibrating against 0 dBm, 50 MHz power
reference. The 11708A is factory set to 30 dB ±0.05 dB at 50 MHz, traceable to
NIST. SWR < 1.05 at 50 MHz.
* The 8480 Series sensors in the table do not include discontinued models.