beautypg.com

Isolated high speed can interface, Trion-can, Cables for trion-can modules – Atec Dewetron-DEWE2_DatatsheetЙ User Manual

Page 38: Options

background image

www.dewetron.com

38

Isolated high speed CAN interface

Input types

High speed, (low speed and single wire with optional converter)

Listen only and programmable termination

Direct interface to CPAD2 module series

TRION-CAN

TRION-CAN specifications
Input channels

2 with DSUB 9 connector (TRION-CAN-2-D)
4 with DSUB 9 connector (TRION-CAN-4-D)

Specification

CAN 2.0B

Physical layer

High speed, (low speed and single wire with optional converter)

Listen only mode

Supported

Termination

Programmable: high impedance or 100 Ω

Galvanic isolation

500 V

DC

Bus pin fault protection

±36 V

CAN Transceiver

SNHVD235

Sensor power supply (per module)

5 V (600 mA) and 12 V (600 mA)

Power consumption

Typ. 5 W + excitation power

Connector

SUB-D-9 plug

Weight

Appr. 190 g

TRION-CAN-4-D

TRION-CAN-2-D

Cables for TRION-CAN modules

TRION cables

Connector

Termination

Length TRION modules

TRION-CBL-D9OE-05-00

DSUB-9

open end

5 m

TRION-CAN-x-D

ADAP-CAN-LS-HS

ADAP-LIN-CAN

Options

ADAP-CAN-LS-HS

DSUB-9

DSUB-9, Adaptor from low-speed CAN to high-speed CAN

ADAP-LIN-CAN

DSUB-9

DSUB-9, Isolated LIN to CAN adaptor. Requests data from LIN

as a LIN-master and outputs the data to CAN

Options

Series Modules