Series modules overview – Atec Dewetron-DEWE2_DatatsheetЙ User Manual
Page 25
25
Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2
Series Modules
Series Modules Overview
V
V
V
Model
Channels
Input type
Sample rate
Resolution
TRION-2402-dSTG
8 (with RJ-45)
8 (with DSUB)
6 (with LEMO 1B)
AC/DC coupled inputs with 4 selectable high pass filters
Voltage: up to ±10 V, single ended/differential
Bridge: full/half/quarter and piezoresistive bridge, incl. shunt calibration
IEPE: 4 mA fixed excitation current
Temperature: Pt100 to Pt 2000
Potentiometer, resistance: 10 Ω to 30 kΩ
204.8 kS/s
per channel
24 bit
TRION-2402-dACC
8 (with SMB)
6 (with BNC)
Voltage: up to ±70 V
DC
or 46.7 V
RMS
AC, single ended/differential, AC/DC coupling
Current: with external shunt resistor
IEPE: programmable excitation current 10 µA to 24 mA, 4 HP filters
Temperature: 2-wire Pt100 to Pt 2000, KTY
Resistance: 10 Ω to 1 MΩ
Counter: AI 1 and AI 2 are internally connected to SuperCounters™ with pro-
grammable threshold levels to support any signal waveform
204.8 kS/s
per channel
24 bit
TRION-2402-V
4 or 8
Voltage: up to ±1000 V, isolated inputs
Current: with external shunt resistor
204.8 kS/s
per channel
24 bit
TRION-CAN
2 or 4
Isolated high speed CAN 2.0B, up to 1 Mbit/s with programmable termination
supports OBDII, J1939, CAN output
n/a
n/a
TRION-CNT
6 CNT / 18 DI
SuperCounter™ inputs with galvanic isolation, 32 bit, 80 MHz
Support sensor mode, event counting and waveform timing
Differential counter inputs with ±100 V input range
AC/DC coupling and programmable threshold levels from 0 to 50 V to support
any signal waveform
Each counter input can be selected to be 3 digital inputs
204.8 kS/s
per channel
80 MHz
TRION-DIO-4800
48 DI
48 digital inputs with galvanic isolation,
Low level: U
IN
< 1.8 V
High level: U
IN
< 3.2 V
Max input level: 35 V continuous (65 V peak)
204.8 kS/s
per channel
80 MHz
TRION-BASE
8 DIO and 8 DI,
2 CNT,
1 SYNC, 1 AUX
8 digital I/Os, 8 digital inputs and 2 SuperCounters™: TTL level with 30 V over-
voltage protection
1 auxiliary programmable input, by default set to camera trigger
1 isolated synchronisation interface to connect another system
204.8 kS/s
per channel
80 MHz
TRION-TIMING
1 IRIG In / Out
8 DIO, 1 CNT
2 SYNC, 1 AUX
Timing: Isolated IRIG input and output
Synchronization: 2 SYNC interfaces
8 digital I/Os, 1 SuperCounter™: TTL level with 30 V overvoltage protection
1 auxiliary programmable input, by default set to camera trigger
204.8 kS/s
per channel
80 MHz
TRION-A429
4, 8, 16 or 30
ARINC 429 channels (RX/TX)
-
8 bit
TRION-M1553
1,2 or 4
MIL-STD-1553 channels (dual redundant, dual- or full-function)
-
8 bit
TRION-MA4
9, 10, 12 or 13
ARINC 429 channels (RX/TX) and
MIL-STD-1553 channels (dual redundant, dual- or full-function)
-
8 bit
TRION-1628-AO-2
2
Analog output module, based on NI PXI-6251
Voltage: up to ±10 V
Update rate max.
2.8 MS/s
16 bit