beautypg.com

Dewe2 mainframes – Atec Dewetron-DEWE2_DatatsheetЙ User Manual

Page 13

background image

13

Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2

DEWE2-M4

DEWE2-M4s

DEWE2-M7s

DEWE2-M13s

DEWE2-M13

Slots for TRION™ acquisition modules

4

4

7

13

13

Dynamic channel expansion

Ethernet

Ethernet

Ethernet

Ethernet

Ethernet

Quasi-static channel expansion

EPAD2

CPAD2 via TRION-CAN

EPAD2

CPAD2 via TRION-CAN

EPAD2

CPAD2 via TRION-CAN

EPAD2

CPAD2 via TRION-CAN

EPAD2

CPAD2 via TRION-CAN

Data storage

1)

Technology

Removable Solid State Disk (SLC type)

Solid State Disk (SLC type)

Solid State Disk (SLC type)

Solid State Disk (SLC type)

Hard disk (plus two 3,5“ bays)

Capacity

120 GB (up to 256 GB)

120 GB (up to 256 GB)

120 GB (up to 256 GB)

120 GB (up to 256 GB)

1 TB

Typ. duration of recording

(16 ch. / 10 kS/s/ch. / 16 bit)

4 days

4 days

4 days

4 days

35 days

Gap free storing rate

2)

Typ. 90 MB/s

Typ. 90 MB/s

Typ. 90 MB/s

Typ. 90 MB/s

Typ. 80 MB/s

Main system

1)

Display

no display

MOB-DISP-12-A recommended

no display

MOB-DISP-12-A recommended

no display

MOB-DISP-12-A recommended

no display

MOB-DISP-12-A recommended

no display

Processor

Intel

®

Core™ i7

Intel

®

Core™ i7

Intel

®

Core™ i7

Intel

®

Core™ i7

Intel

®

Core™ i7

Power supply

Standard: rated (max.)

11 to 32 V

DC

(10 to 36 V

DC

)

isolated;

incl. external AC power supply

11 to 32 V

DC

(10 to 36 V

DC

)

isolated;

incl. external AC power supply

11 to 32 V

DC

(10 to 36 V

DC

)

isolated;

incl. external AC power supply

11 to 32 V

DC

(10 to 36 V

DC

)

isolated;

incl. external AC power supply

100 to 240 V

AC

(90 to 264 V

AC

)

Optional

add internal buffer battery

for ~ 10 min. operation and/or

DW2-UPS-150-DC (ext. battery pack)

add internal buffer battery

for ~ 10 min. operation

add internal buffer battery

for ~ 10 min. operation

add internal buffer battery

for ~ 5 min. operation

Redundant AC power supply

Environmental

Operating temperature

0 to +50 °C, down to -20 °C with prewarmed unit

0 to +50 °C, down to -20 °C with prewarmed unit

0 to +50 °C, down to -20 °C with prewarmed unit

0 to +50 °C, down to -20 °C with prewarmed unit

0 to +50 °C, down to -20 °C with prewarmed unit

Storage temperature

-20 to +70 °C

-20 to +70 °C

-20 to +70 °C

-20 to +70 °C

-20 to +70 °C

Humidity

10 to 80 % non cond.,

5 to 95 % rel. humidity

10 to 80 % non cond.,

5 to 95 % rel. humidity

10 to 80 % non cond.,

5 to 95 % rel. humidity

10 to 80 % non cond.,

5 to 95 % rel. humidity

10 to 80 % non cond.,

5 to 95 % rel. humidity

Max. Altitude

2000 m (6560 ft)

2000 m (6560 ft)

2000 m (6560 ft)

2000 m (6560 ft)

2000 m (6560 ft)

Sine vibration (EN 60068-2-6)

20 m/s²

20 m/s²

20 m/s²

20 m/s²

20 m/s²

Shock (EN 60028-2-27)

30 g

30 g

30 g

30 g

15 g

Random vibration (EN 60721-3-2)

Class 2M3

Class 2M3

Class 2M3

Class 2M3

Class 2M2

Dimensions

Dimensions (W x D x H)

(without handle)

318 x 253 x 108 mm

(12.5 x 10 x 4.3 in.)

177 x 230 x 177 mm (4 u)

(7 x .9.1 x 7 in.) without feet

258 x 230 x 177 mm (4 u)

(10.2 x 9.1 x 7 in.) without feet

441 x 230 x 177 mm

(4 u plus 1 u for cooling in cabinet required)

(17.4 x 9.1 x 7 in.) without feet

441 x 427 x 177 mm

(4 u plus 1 u for cooling in cabinet required)

(17.4 x 16.8 x 7 in.) without feet

Weight without TRION™ modules

Typ. 3.9 kg (8.6 lb.)

Typ. 3.9 kg (8.6 lb.)

Typ. 4.9 kg (10.8 lb.)

Typ. 13.0 kg (28.6 lb.)

Typ. 13.0 kg (28.6 lb.)

1)

Please find current specifications in the latest price list

2)

Depending on configuration (performance is different if e.g. Video data are involved and 2 or more files are written in parallel)

3)

Weight of one battery: 660 g (1.45 lb.)

DEWE2-M13-MK
19“ mounting kit for the
DEWE2-M13 series, 4U

MOB-DISP-12-A
Very rugged
external display

DEWE2 Mainframes