Atec Anritsu_MT8801C User Manual
Page 19
![background image](/manuals/317985/19/background.png)
19
◆ MX880115A GSM Measurement Software (extracts)
T
ransmission measur
ement
Reception measur
ement
Frequency/
Frequency range: 10 MHz to 2.2 GHz
modulation
Residual phase error accuracy:
Յ
0.5° rms,
Յ
2° peak
measurement
Input level range: –5 to +40 dBm (average power within burst, MAIN connector)
Amplitude
Calibration input level range: +10 to +40 dBm (average power within burst, MAIN connector)
measurement
Transmission power accuracy: ±0.4 dB (+10 to +40 dBm), ±0.7 dB (–5 to +40 dBm)
∗
MAIN connector, after calibration by using built-in power meter with same Tx reference level as calibration
Output RF spectrum
Modulation portion measurement range:
Ն
50 dB (200 kHz offset),
Ն
66 dB (
Ն
250 kHz offset)
measurement
Transition portion measurement range:
Ն
57 dB (
Ն
400 kHz offset)
All measurement
Measurement time:
Յ
2.0 s (amplitude measurement: normal mode, except MS report measurement)
items
Frequency range: 10 MHz to 3 GHz
Signal generator
Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Phase error:
Յ
1° rms,
Յ
4° peak
Error rate
Measurement pattern: 11 test patterns selectable
measurement
Number of measurement samples: 1 to 99999999 (FER/CRC, C
I
b, C
II
, FAST)
Call processing
Pass/fail judgment of registration, origination, termination, communication, hand-over, disconnection from
network, disconnection from mobile station
Analog measurement
Same as Option 01 for AMPS
◆ MX880116A PDC Measurement Software with Call Processing (extracts)
Transmission measur
ement
Reception measur
ement
◆ MX880117A PHS Measurement Software with Call Processing (extracts)
Transmission measur
ement
Reception measur
ement
Frequency/
Frequency range: 10 MHz to 2.2 GHz
modulation
Modulation accuracy: ±(2% of indicated value + 0.5%)
measurement
Amplitude
Input level range: +10 to +40 dBm (average power with burst, MAIN connector)
measurement
Transmitter power accuracy: ±10% (MAIN connector, after calibration by using built-in power meter)
Adjacent channel
power measurement
Measurement range:
Ն
60 dB (50 kHz offset),
Ն
65 dB (100 kHz offset)
Batch measurement
Measurement time:
Յ
1.5 s (amplitude measurement in normal mode; occupied bandwidth and adjacent
functions
channel power measurement on high-speed mode)
Frequency range: 10 MHz to 3 GHz
Signal generator
Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Modulation accuracy:
Յ
3%rms
Error rate
Measurement pattern: PN9, PN15
measurement
Number of measurement bits: 10
2
, 10
3
, 2556, 10
4
, 10
5
, 10
6
,
∞
Call processing
Pass/fail judgment of registration, origination, termination, communication, hand-over, disconnection from
network, disconnection from mobile station
Frequency/
Frequency range: 10 MHz to 2.2 GHz
modulation
Modulation accuracy: ±(2% of indicated value + 0.7%)
measurement
Amplitude
Input level range: +10 to +40 dBm (average power with burst, MAIN connector)
measurement
Transmitter power accuracy:
±10% (MAIN connector, after calibration by using built-in power meter, at +10 to +40 dBm)
Adjacent channel
power measurement
Measurement range:
Ն
60 dB (600 kHz offset),
Ն
65 dB (900 kHz offset)
Batch measurement
Measurement time:
Յ
1.5 s (amplitude measurement in normal mode; occupied bandwidth and adjacent
functions
channel power measurement on high-speed mode)
Frequency range: 10 MHz to 3 GHz
Signal generator
Level range: –133 to –13 dBm (MAIN connector), –133 to +7 dBm (AUX connector)
Modulation accuracy:
Յ
3%rms
Error rate
Measurement pattern: PN9, PN15
measurement
Number of measurement bits: 10
2
, 10
3
, 2556, 10
4
, 10
5
, 10
6
,
∞
Call processing
Pass/fail judgment of registration, origination, termination, communication, hand-over, disconnection from
network, disconnection from mobile station