5 dpm leds and connections, Fig. 7-6, dpm leds and connectors, 0 installation – Alpha Technologies DSM3 for XM3 - Technical Manual User Manual
Page 69

69
745-814-B11-001, Rev. C (03/2014)
7.5
DPM LEDs and Connections
Item LED or Connector
Status
Behavior
Indication
1
ALM/RDY: Alarm and
Ready
N/A
OFF
No power or malfunctioning Communications
Module
GRN
ON
Communications Module reset in process
Steady Blinking Normal operation
RED
Blinking more
OFF than ON
Minor Alarm
Blinking more
ON than OFF
Major Alarm
2
REG: Upstream
ranging and
registration lock
GRN
OFF
No power, upstream frequency undetermined
BLINKING
Power on, downstream locked, upstream
frequency ranging, DHCP request in progress
ON
CMTS registration completed
3
DS: Downstream RF
Carrier detection and
lock.
GRN
OFF
No power / downstream carrier
BLINKING
Power on, downstream carrier frequency searching
ON
Downstream carrier lock
4
ACT: CPE Activity
status
GRN
OFF
No Ethernet communications activity
BLINKING
Momentary flashes during CPE communications
via the Ethernet Craft port
5
LNK: CPE Link status
GRN
OFF
No Ethernet link
ON
Link on Ethernet Craft port
6
RF Rx/Tx Power Level
Indicator
TRI
OFF
No RF detected
Blue
Rx/Tx Power at a warning level as set within the
SCTE-HMS Property Table
Green
Rx/Tx RF Power level within tolerance
Red
Rx/Tx Power at an alert level as set within the
SCTE-HMS Property Table
7
RST: Reset Buttton
8
ENV: Environmental Control Connector
9
TPR: Tamper Switch Connector
10
ETH: Ethernet Connection
11
RF Connection
12
CM, CPE MAC Address Label
Fig. 7-6, DPM LEDs and Connectors
7.0 Installation
7
8
10
1
2
3
4
5
9
11
6
Note: The DPM requires the XM3 Smart AlphaGuard (SAG) option for individual battery voltage measurements.
12