0 network configuration – Alpha Technologies DSM3 for XM3 - Technical Manual User Manual
Page 18

18
745-814-B11-001, Rev. C (03/2014)
DOCSIS configuration files vary from system to system. Take into consideration your company's policies, and
test the file on a local system prior to widescale deployment.
NOTE:
In previous versions of the DSM product line, an additional configuration file (also known as a Setup File)
could be used for distributing custom Alpha MIB settings to all DSMs on a network. This is still the case,
with the only difference being the name of the file, which for the DSM3 Series is atidoc03.cfg. It may be
used if preferred, but is not required.
3.0 Network Configuration
3.3
The DOCSIS Configuration File
3.3.6 Sample DOCSIS Configuration File Entries — DOCSIS 2.0+IPv6
A
B
C
D
E
SNMPv1v2c Coexistence Configuration
SNMPv1v2c Community Name:ReadWrite
SNMPv1v2c Transport Address Access
SNMPv1v2c Transport Address:0.0.0.0/0
SNMPv1v2c Transport Address Mask:0.0.0.0/0
SNMPv1v2c Transport Address Access
SNMPv1v2c Transport Address:0:0:0:0:0:0:0:0/0
SNMPv1v2c Transport Address Mask:0:0:0:0:0:0:0:0/0
SNMPv1v2c Access View Type:read-write
SNMPv1v2c Access View Name:docsisManagerView
Docsis V3 Notification Receiver
UDP Port number of trap receiver:162
Type of trap:SNMP v1 trap in an SNMP v1 packet
Timeout for sending inform:15000
Number of retries:3
Filtering Parameters:1.3.6
IPv6 Address of trap receiver:fc00:168:1:0:0:0:0:32
Docsis V3 Notification Receiver
IP Address of trap receiver:192.168.1.51
UDP Port number of trap receiver:162
Type of trap:SNMP v1 trap in an SNMP v1 packet
Timeout for sending inform:15000
Number of retries:3
Filtering Parameters:1.3.6
Software Upgrade Filename:ModemFirmwareFile.bin
Software Upgrade IPv6 TFTP Server:fc00:168:1:0:0:0:0:51
Manufacturer Code Verification Certificate:3082031B30820…
Manufacturer Code Verification Certificate:040A1312414C5…
Manufacturer Code Verification Certificate:FF040C300A060…
Manufacturer Code Verification Certificate:257939C848CE0…
Sets Read-Write community string. Set the IP address, netmask and community string to fit your system.
Sets the IP address of where the SNMP traps will be sent. This is typically set to match the IP address of the Network
Managements System Server.
Sets firmware download parameters.
Specifies the IP address of the TFTP server used for upgrading firmware.
Sets Code Verification Certificate (CVC) for firmware upgrade security per the DOCSIS specification.
A
B
C
D
E
Legend
:
Fig. 3-3, Sample DOCSIS Configuration File — DOCSIS 2.0+IPv6