beautypg.com

ABUS AZWG10000 Profiline GSM-Interface II User Manual

Page 36

background image

36

AZWG10000

Reset
Battery

A message is sent when the
battery voltage is normal again
(> 11 V DC).

“GSM battery OK”

SIM validity

A message is sent 30 days
before expiry of the SIM card.

“SIM expire in 1 month”

Test message

Transmission of a test message.
The period duration is defined
under “repetitions”.

“Periodic test”

Message
provider

Transmission of messages of
SIM provider

-


The text message (SMS) is sent in the following format:

Message structure

Example

Security

system

Time 01/06/2008

13:35

Trigger/event Intruder

Alarm

Basement door

8.5

Follow Me Parameters

8.5.1 General

With the GSM-Interface, you can send voice messages and text messages (SMS
texts) to up to 8 contact telephone numbers. To define the contacts, you specify
their telephone numbers for transmission over an analogue telephone line (PSTN).
You define settings for a possible GSM transmission in the dialling code settings.

8.5.2

Dialling code settings

With the interface function, you can simulate an analogue telephone line over the
GSM network. If the analogue telephone line fails or if no analogue telephone line is
available, the device automatically switches to GSM operation.
This is often useful if the GSM-Interface is connected with an alarm centre that
sends protocols to an emergency service. Possible protocols are the normal
European standards Contact ID and SIA.
The dialling code settings are necessary if transmission is by GSM network instead
of PSTN. Because of codes needed for getting an outside line, dialling codes, etc.,
it is important to make the right settings for transmission to be successful.

IMPORTANT:

You will find the dialling code settings in the GSM software under
“General>>>Extended Menu or under “10.2.2 Parameters” in the SMS commands.