Performing soft system resets (resets 3, 4, and 5), Operation, cont’d – Extron Electronics MAV Plus series Large Scale User Guide User Manual
Page 80

Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-48
Performing soft system resets (reset modes 3, 4, and 5)
Perform a soft reset of the switcher as follows:
1
.
Use an Extron Tweeker or other small screwdriver to press and hold the rear
panel Reset button until the rear panel Reset LED and the front panel View
and Esc buttons blink once (events reset), twice (system reset), or three times
(absolute reset).
RESET
Rx
RESET
RESET
RESET
Rx
RESET
RESET
RESET
Rx
RESET
RESET
I / O
RGBHV AUDIO
I / O
RGBHV AUDIO
I / O
RGBHV AUDIO
Front panel I/O buttons flash
once.
Front panel I/O buttons flash
twice.
Front panel I/O buttons flash
three times.
Press and
hold
the Reset button.
Release, then
immediately
press and release.
Release, then
immediately
press and release.
Release, then
immediately
press and release.
3 seconds
Events Reset
(Mode 3)
IP Settings
Reset
(Mode 4)
Reset LED
flashes
once.
1
Press and
hold
the Reset button.
6 seconds
Reset LED
flashes
twice.
2
Absolute
Reset
(Mode 5)
Press and
hold
the Reset button.
9 seconds
Reset LED
flashes
three
times.
3
Reset LED
flashes
four
times.
3
Reset LED
flashes
four
times.
3
Reset LED
flashes
four
times.
3
2
.
Release the Reset button and then immediately press and release the Reset
button again. Nothing happens if the second momentary press does not occur
within 1 second.