Operation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Operation
3-26
5
.
Select a different I/O group
: Press and release the Preset button to select
group 2.
C O N T R O L
PRESET
ENTER
ESC
VIEW
1
3
2
4
Press and release the Preset button to select group 2.
The button lights to indicate the selection.
Group #
6
.
Assign inputs and outputs
: Press and release the input 5 through 8 and
output 5 through 8 buttons.
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
I
N
P
U
T
S
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
I
N
17 18 19 20 21 22 23 24
1 2 3 4 5 6 7 8
25
9
O
U
T
Press and release the Input 5 through Input 8 buttons. The selected buttons light.
Press and release the Output 5 through Output 8 buttons. The selected buttons light.
7
.
Exit
I/O Group mode
: Simultaneously press and release the RGBHV
(CrossPoint switchers) or Video (MAV Plus switchers) button and the Audio
button. The switcher exits I/O Group mode.
I / O
VIDEO
AUDIO
Press and release both buttons.
N
As an alternative, if you do not push any front panel buttons for approximately
30 seconds, the front panel times out and the switcher exits
I/O Group mode.
• Group 1 consists of inputs 1 through 4 and outputs 1 through 4.
• Group 2 consists of inputs 5 through 8 and outputs 5 through 8.