Installation, cont’d
CrossPoint 450 Plus and MAV Plus Switchers • Installation
2-8
g
BME COMM interconnect ports —
If the matrix switcher system consists of
more than one BME, the BMEs must be connected together in a daisy chain
using Extron-supplied RJ-45 cables.
a
. Connect the first daisy chain from BME 0’s BME Comm Out connector to
the nearest BME’s BME Comm In connector (figure 2-9). In a rack where
BMEs are arranged so that their physical location matches the BME
address numbering, this would be BME 1. But since not all systems are
configured alike, call this module BME n.
64
63
62
61
LAN
ACT LINK
RESET
REMOTE
Rx
Tx
Rx
Tx
4
-
+
BME COMM
IN
OUT
BME
ADDRESS
EXT
SYNC
Rx
Tx
8
9 10
6
11
7
RESET
REMO
TE
Rx
Tx
Rx
Tx
LAN
ACT
LINK
64
63
62
61
BME COMM
OUT
IN
BM
E
ADD
RES
S
EXT
SYNC
4
From previous BME
To next BME
Figure 2-9 — Daisy-chaining BMEs (video BME shown)
b
. Connect the next RJ-45 cable from BME n’s BME Comm Out connector to
the nearest unconnected BME’s (BME n+1’s) BME Comm In connector.
c
. Continue connecting RJ-45 cables from each daisy-chained module’s BME
Comm Out connector to the next module’s BME Comm In connector
until all modules are included in the chain. When all of the BMEs are
connected, each of the BMEs in the system is connected to at least one
other BME via the BME Comm connectors.