Ethernet-connected firmware upload, Ethernet-connected.firmware.upload -15 – Extron Electronics MAV Plus series Large Scale User Guide User Manual
Page 127
![background image](/manuals/312291/127/background.png)
5-15
CrossPoint 450 Plus and MAV Plus Switchers • Matrix Software
7
.
Connect a Windows-based computer to either switcher serial port or the
switcher LAN port. See chapter 2, “Installation”, for more details.
8
.
Start the Matrix Switchers Control Program and connect to the
matrix switcher. See “Using the Matrix Switcher Control software” in this
chapter, steps 1 through 4, starting on page 5-4.
9
.
Click Tools > Update firmware.
If you are connected via the LAN port
, the Select Files window appears
(figure 5-10). See “Ethernet-connected firmware upload”, below.
If you are connected via either serial port
, either the Add Device window
(figure 5-11) or the Extron Firmware Loader (figure 5-12) appears. See “Serial-
port-connected firmware upload”, on the next page.
Ethernet-connected firmware upload
11
Figure 5-10 — Select files window
10
. Navigate to the folder where you saved the firmware upgrade file. Select the
file.
N
Valid firmware files must have the file extension .S19. Any other file extension
is not a firmware upgrade.
N
The original factory-installed firmware is permanently available on the matrix
switcher. If the attempted firmware upload fails for any reason, the switcher
reverts to the factory-installed firmware.
11
. Click the Open button. The software advises you that you are about to
reprogram the switcher’s firmware. Click OK to continue.
A status window, which shows the progress of
the upload, appears. The firmware upload to the
matrix switcher may take a few minutes.