beautypg.com

Resetting, Attention, Figure 26. volume indicator leds – Extron Electronics SCP 104 Series User Guide User Manual

Page 32

background image

f

Volume knob and indicator LEDs — Turn this knob to

adjust the volume on the input that is currently selected.
The five LEDs light incrementally, bottom to top, to indicate
the current volume level, as shown in figure 26. The top LED
is red; the others are green.

VOLUME

VOLUME

VOLUME

VOLUME

LED Off

LED Blinking

LED On

0% (Min) or Mute

1-19%

20-39%

40-59%

60-89%

90-100% (Max)

VOLUME

VOLUME

Figure 26.

Volume Indicator LEDs

g

Faceplate attachment screws — These four screws (six, on

the SCP 226 AAP) secure the faceplate to the SCP.

ATTENTION:

Do not remove these screws after the SCP

has been installed in a wall or lectern.

Resetting

To reset the SCP to the factory default version of the firmware,
press and hold the buttons numbered 1 and 3 on the front
panel while applying power to the unit.

SCP 104

PROJECTOR

VOLUME

ON

OFF

1

2

3

4

To reset, press and
hold these buttons
simultaneously
while applying
power.

Figure 27.

Resetting the SCP 104 to Factory Defaults

SCP 104 and SCP 226 • Installation and Operation

26

This manual is related to the following products: