Extron Electronics DSC 301 HD User Guide User Manual
Page 36

Command
ASCII Command
(host to scaler)
Response
(scaler to host)
Additional Description
Input presets
Recall preset
2*X2).
2RprX2)]
Recall input preset
X2)
for selected
input.
Save preset
2*X2),
2SprX2)]
Save input preset
X2)
for selected
input.
Delete/clear preset
E
X2*X2)PRST}
PrstX2*X2)]
Clears input preset
X2)
, and sets input
preset
X2)
name to [unassigned].
Input preset name
Write name
E
2*X2),X1#PNAM}
Pnam2*X2),X1#]
Set the input preset
X2)
to
X1#
.
Read name
E
2*X2)PNAM}
X1#]
Read the name for input preset
X2)
.
NOTE:
Unassigned presets = “
[unassigned]”. To restore a default user preset name, enter a single space character for
X1#
. Valid only
for previously saved presets.
User Presets
Input Presets
Color
H/V Image
Position
Color
H/V Image
Position
Input Type
H Start
Tint
H/V Image
Size
Tint
H/V Image
Size
Audio Gain/
Attenuation
V Start
Contrast
Preset Name
Contrast
Preset Name
Film Mode
H Active
Brightness
Brightness
Total Pixels
V Active
Detail
Detail
Phase
Figure 18.
Values Saved in User and Input Presets
Auto memories (per input)
Enable
E
X!
*1AMEM}
Amem
X!
*1
]
Set auto memory on. Previous settings
for incoming signal are auto recalled.
Disable
E
X!
*0AMEM}
Amem
X!
*0
]
Set auto memory off. Manual recall
of input presets needed to configure
input.
View setting
E
X!
AMEM}
X(]
View current auto memory for input
X!
.
NOTE:
X!
= Input selection:
1
to
3
X(
= Enable or disable:
0
= Off or disable,
1
= On or enable
X1#
= Text label or preset name, up to 16 characters
X2)
= Input presets,
1-128
(global)
DSC 301 HD • SIS Communication and Control