beautypg.com

Signal test points – Extron Electronics CS 120P User Guide User Manual

Page 28

background image

Wiring Multiple Speakers Using Loop-through:
A loop-through electrical connection is made on the crossover board of the CS 26T.
Connect the wires to the captive screw connectors of the speakers, as shown in
figure 36. Be sure to tighten the screws.

Speaker 1

Speaker 2

Wiring Multiple Speakers Using Loop-through

IN

LOOP

IN

+

LOOP

+

IN

LOOP

IN

+

LOOP

+

(Black)

(Red)

(Red)

(Red)

(Black)

(Black)

Power Amplifier

Figure 36.

Wiring Multiple Speakers Using Loop-through

In this configuration, all of the speakers downstream of the one being tested are

disconnected from the signal when it is disconnected. This is useful for

troubleshooting in three ways:

The system is sectioned for easier troubleshooting.

The source signal can be tested by connecting to the inner + (IN) and – (IN)

terminals of the captive screw connector, as shown in figure 37.

Signal Test Points

Red Wire (+) from Amplifier

Black Wire (-) from Amplifier

Amplifier

Test Points

Figure 37.

Signal Test Points — Loop-through Configuration

CS 26T and CS 120P User Guide • Installation

22

This manual is related to the following products: