Extron Electronics CS 120P User Guide User Manual
Page 23
7.
Route the cables through the cover plate —
NOTES:
•
The CS 120P is fully UL 2043 compliant only when it is used with a metal
conduit or with plenum rated cables.
•
Installation of all conduits, conduit adapters, wiring, and electrical connections
must conform to all applicable building codes and local ordinances.
Using a flexible conduit:
a.
Route wires through the conduit.
b.
Insert the conduit into the cover plate opening using an appropriate conduit
adapter, and secure the conduit to the plate as shown in figure 27.
c.
Pull the wires out of the conduit and through the cover plate.
with flexible conduit
Flexible Conduit Adapter
Flexible Conduit
Cover Plate
Seismic Cable Pass
Through Loop
Rear of Speaker
Figure 27.
Routing the Cables through the Cover Plate Using a Flexible
Conduit
Using speaker wires without a conduit:
a.
Secure the cable clamp adapter (included) to the cover plate.
b.
Insert the wires through the clamp and cover plate, as shown in figure 28.
c.
Tighten the clamp screws.
Cable Clamp Adapter
Cover Plate
Seismic Cable Pass
Through Loop
Rear of Speaker
Figure 28.
Routing the Cables Without a Conduit
CS 26T and CS 120P User Guide • Installation
17