beautypg.com

Extron Electronics CS 120P User Guide User Manual

Page 12

background image

8.

Route the cables through the cover plate

NOTES:

The CS 120P is fully UL 2043 compliant only when it is used with a metal
conduit or with plenum rated cables.

Installation of all conduits, conduit adapters, wiring, and electrical connections
must conform to all applicable building codes and local ordinances.

Using a flexible conduit:

a.

Route wires through the conduit.

b.

Insert the conduit into the cover plate opening using an appropriate conduit
adapter, and secure the conduit to the plate as shown in figure 6.

c.

Pull the wires out of the conduit and through the cover plate.

with flexible conduit

Flexible Conduit Adapter

Flexible Conduit

Cover Plate

Seismic Cable Pass

Through Loop

Rear of Speaker

Figure 6.

Routing the Cables through the Cover Plate Using a Flexible
Conduit

Using speaker wires without a conduit:

a.

Secure the cable clamp adapter (included) to the cover plate.

b.

Insert the wires through the clamp and cover plate, as shown in figure 7.

c.

Tighten the clamp screws.

Cable Clamp Adapter

Cover Plate

Seismic Cable Pass

Through Loop

Rear of Speaker

Figure 7.

Routing the Cables Without a Conduit

CS 26T and CS 120P User Guide • Installation

6

This manual is related to the following products: