12a digital slimlynx, Open frame: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12A Digital SlimLynx Open Frame User Manual
Page 30

GE
Data Sheet
12A Digital SlimLynx
TM
Open Frame: Non-Isolated DC-DC Power Modules
3Vdc –14.4Vdc input; 0.45Vdc to 5.5Vdc output; 12A Output Current
February 19, 2014
©2014 General Electric Corporation. All rights reserved.
Page 30
Table 6 (continued)
Hex
Code
Command
Brief Description
Non-Volatile
Memory Storage
61 TON_RISE
Sets the rise time of the output voltage during startup. Supported values are
0.6ms, 0.9ms, 1.2ms, 1.8ms, 2.7ms, 4.2ms, 6.0ms, 9.0ms
Format
Linear, two’s complement binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r/w
Function
Exponent Mantissa
Default Value
1 1 1 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r/w r/w r/w
r/w
r/w
r/w
r/w r/w
Function
Mantissa
Default Value
0 0 1 0 1 0 1 0
YES
78 STATUS_BYTE
Returns one byte of information with a summary of the most critical module
faults
Format
Unsigned Binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
X OFF
VOUT
_OV
IOUT_
OC
VIN_U
V
TEMP CML OTHE
R
Default Value
0 0 0 0 0 0 0 0
79 STATUS_WORD
Returns two bytes of information with a summary of the module’s fault/warning
conditions
Format
Unsigned Binary
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
VOUT IOUT_
OC
X X
PGOO
D
X X X
Default Value
0 0 0 0 0 0 0 0
Bit Position
7 6 5 4 3 2 1 0
Access
r r r
r
r
r
r r
Flag
X OFF VOUT
_OV
IOUT_
OC
VIN_U
V
TEMP CML OTHE
R
Default Value
0 0 0 0 0 0 0 0
7A STATUS_VOUT
Returns one byte of information with the status of the module’s output voltage
related faults
Format
Unsigned Binary
Bit Position
7
6 5
4
3 2 1 0
Access
r r
r
r
r
r
r r
Flag
VOUT_OV X X VOUT_UV X X X X
Default Value
0
0 0
0
0 0 0 0
7B STATUS_IOUT
Returns one byte of information with the status of the module’s output current
related faults
Format
Unsigned Binary
Bit Position
7 6 5 4
3
2
1
0
Access
r r r
r
r
r
r r
Flag
IOUT_OC X
IOUT_OC_WARN X X X
X X
Default Value
0 0 0 0
0
0
0
0