Data Sheet
March 7, 2012
NQR010A0X4: Non-Isolated DC-DC Power Modules
4.5 – 14Vdc input; 0.59Vdc to 6Vdc Output; 10A output current
LINEAGE
POWER
11
Characteristic Curves (continued)
The following figures provide typical characteristics for the NQR010 module at 5Vout and at 25ºC.
EF
FI
CI
EN
C
Y
, η
(%)
70
75
80
85
90
95
100
0
2
4
6
8
10
Vin = 6.5V
Vin = 14V
Vin = 12V
O
U
TP
UT
CU
RRE
NT
, Io
(A
)
3
4
5
6
7
8
9
10
11
25
35
45
55
65
75
85
2m/s
(400LFM)
NC
1.5m/s
(300LFM)
1m/s
(200LFM)
0.5m/s
(100LFM)
OUTPUT CURRENT, I
O
(A)
AMBIENT TEMPERATURE, T
A
O
C
Figure 31. Converter Efficiency versus Output Current.
Figure 32. Derating Output Current versus Ambient
Temperature and Airflow.
O
U
TP
U
T
VOLTAGE
V
O
(V
) (2
0m
V
/d
iv)
OU
TP
U
T
CU
RR
ENT
,
OUT
P
UT
VO
LT
A
G
E
I
O
(A
)
(5
A
div
)
V
O
(
V
) (
500mV/
di
v)
TIME, t (1
μs/div)
TIME, t (100
μs /div)
Figure 33. Typical output ripple and noise (V
IN
= 12V, I
o
= I
o,max
).
Figure 34. Transient Response to Dynamic Load
Change from 0% to 50% to 0% with V
IN
=12V.
OU
TP
U
T
VOLTAG
E
ON/
O
FF V
O
LTAG
E
V
O
(V
) (2
V
/d
iv)
V
ON
/OFF
(V
)
(5
V/d
iv)
OU
TP
U
T
VOL
T
A
G
E
IN
PU
T
VO
LTAG
E
V
O
(
V
) (2
V/d
iv)
V
IN
(
V
) (
5V
/d
iv
)
TIME, t (2ms/div)
TIME, t (2ms/div)
Figure 35. Typical Start-up Using On/Off Voltage (I
o
=
I
o,max
).
Figure 36. Typical Start-up Using Input Voltage (V
IN
=
12V, I
o
= I