GE Industrial Solutions Evolution Series E9000 User Manual
Page 28
![background image](/manuals/295599/28/background.png)
27
Evolution Series E9000 Installation & Maintenance Guide
Size 3 (Standard and Ambient Comp.) cont.
Size 4 (Standard)
Size 4 (Ambient Comp.)
Size 5 (Standard and Ambient Comp.)
Size 0 and 1 (Standard)
Size 1 (Standard)
Motor Full-
Heater
SE
Mag-Break
Load Amps
Number
Rating
Trip Setting
3-Ph, 3 Heater
CR123
Plug
Rec.
Max.
18.0-19.7
C214B
30
3
5
19.8-21.2
C228B
30
3
5
21.3-22.3
C250B
30
3
6
22.4-23.5
C273B
40
2
5
23.6-25.5
C303B
40
3
5
25.6-27.0
C330B
40
3
5
Motor Full-
Heater
SE
Mag-Break
Load Amps
Number
Rating
Trip Setting
3-Ph, 3 Heater
CR123
Plug
Rec.
Max.
.65-.74
C087A
3
LO
LO
.75-.84
C097A
3
LO
LO
.85-.92
C109A
3
LO
LO
.93-1.02
C118A
3
LO
2
1.03-1.10
C131A
3
LO
2
1.11-1.23
C148A
3
LO
2
1.24-1.38
C163A
3
LO
3
1.39-1.49
C184A
3
LO
4
1.50-1.67
C196A
3
LO
4
1.68-1.79
C220A
3
LO
5
1.80-1.98
C239A
3
2
5
1.99-2.24
C268A
3
3
5
2.25-2.43
C301A
3
3
6
2.44-2.75
C326A
7
LO
3
2.76-3.25
C356A
7
LO
4
3.26-3.43
C379A
7
LO
4
3.44-4.03
C419A
7
2
4
4.04-4.43
C466A
7
2
5
4.44-4.94
C526A
7
3
5
4.95-5.36
C592A
7
3
6
5.37-5.77
C630A
7
4
6
5.37-5.77
C630A
15
LO
3
5.78-6.35
C695A
15
LO
3
6.36-6.92
C778A
15
LO
4
6.93-7.99
C867A
15
2
4
8.00-8.47
C955A
15
2
5
8.48-9.19
C104B
15
3
5
9.20-10.0
C113B
20
2
4
10.1-10.7
C125B
20
2
5
10.8-12.0
C137B
20
2
5
12.1-12.9
C151B
20
3
5
13.0-15.1
C163B
20
4
6
15.2-16.3
C180B
25
3
5
16.4-17.9
C198B
25
3
6
Motor Full-
Heater
TEC &
Mag-Break
Load Amps
Number
TECL
Trip Setting
3-Ph, 3 Heater
CR 123
Rating
Rec.
Max.
106-115
C592A
550-1670
2
6
116-125
C630A
550-1670
3
7
126-135
C695A
550-1670
3
7
126-135
C695A
1000-3300
LO
3
136-151
C778A
1000-3300
LO
3
152-164
C867A
1000-3300
LO
4
165-179
C955A
1000-3300
1
5
180-195
C104B
1000-3300
2
5
196-215
C113B
1000-3300
2
6
216-231
C125B
1000-3300
3
6
232-255
C137B
1000-3300
4
7
256-270
C151B
1000-3300
4
HI
Motor Full-
Heater
TEC &
Mag-Break
Load Amps
Number
TECL
Trip Setting
3-Ph, 3 Heater
CR 123
Rating
Rec.
Max.
28.8-32.0
F357B
50
2
4
32.1-34.2
F395B
50
2
5
34.3-36.7
F430B
50
2
6
36.8-43.4
F487B
50
3
7
36.8-43.8
F487B
100
LO
2
43.9-46.6
F567B
100
2
3
46.7-52.6
F614B
100
1
3
52.7-55.6
F658B
100
1
4
55.7-58.7
F719B
100
2
5
58.8-67.1
F772B
100
2
5
67.2-70.6
F848B
100
3
6
70.7-76.3
F914B
100
3
7
76.4-86.9
F104C
100
4
8
76.4-88.7
F104C
150
LO
2
88.8-93.4
F114C
150
1
3
93.5-105
F118C
150
1
3
106-114
F133C
150
1
4
115-128
F149C
150
2
5
129-130
F161C
150
2
6
Motor Full-
Heater
TEC &
Mag-Break
Load Amps
Number
TECL
Trip Setting
3-Ph, 3 Heater
CR 123
Rating
Rec.
Max.
28.8-32.0
F357B
50
1
4
32.1-34.2
F395B
50
2
5
34.3-36.7
F430B
50
2
6
36.8-43.4
F487B
50
3
7
43.5-43.9
F487B
100
1
3
44.0-46.6
F567B
100
1
3
46.7-52.6
F614B
100
1
3
52.7-55.6
F658B
100
1
4
55.7-58.7
F719B
100
2
5
58.8-67.1
F772B
100
2
5
67.2-70.6
F848B
100
3
6
70.7-76.3
F914B
100
3
7
70.7-76.3
F914B
150
LO
1
76.4-86.9
F104C
100
4
8
76.4-88.7
F104C
150
LO
2
88.8-93.4
F114C
150
1
3
93.5-102
F118C
150
1
3
103-110
F133C
150
1
4
111-122
F149C
150
1
4
123-131
F161C
150
2
5
Motor Full-
Heater
TEC &
Mag-Break
Load Amps
Number
TECL
Trip Setting
3-Ph, 3 Heater
CR 123
Rating
Rec.
Max.
55.5-63.3
F772B
100
1
5
63.4-66.1
F848B
100
2
6
66.2-73.5
F914B
100
2
6
73.6-82.2
F104C
100
2
7
82.3-86.9
F114C
100
3
9