Feature specifications (cont.), Environmental specifications, Clp0212 open frame power supply – GE Industrial Solutions CLP0212 User Manual
Page 4: Preliminary data sheet

GE
Preliminary Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
October 11, 2013
©2012 General Electric Corporation. All rights reserved.
Page 4
Feature Specifications (cont.)
Parameter
Device
Min
Typ
Max
Unit
Input Undervoltage lockout
Turn-on Threshold (100% load)
All
86
Vac
Turn-off Threshold (100% load)
All
82
Vac
DC OK – open collector, High when output available
Sink Current
All
4
mA
Maximum Collector Voltage
All
12
V
Environmental Specifications
Parameter
Device
Specification
Conducted Emissions
All
CISPR22 (EN55022) Class A with 3dB margin
Input Harmonics
All
EN61000-3-2
ESD
All
IEC 61000-4-2, Level 3
Radiated Immunity
All
IEC 61000-4-3, Level 2*
Electrical Fast Transient Common Mode
All
IEC 61000-4-4, Level 3
Surge Immunity
All
IEC 61000-4-5, Level 3
Conducted RF Immunity
All
IEC 61000-4-6, Level 3
Voltage Dips
All
EN61000 4.11, Level 3, Class B, C
Shock and Vibration
Operating Shock
All
Three shocks, 15G peak, 11ms sine wave, two axes
Non-Operating Shock
All
Three shocks, 50G peak, 11ms sine wave, two axes
Operating and Non-Operating Vibration
All
5 – 9Hz, 0.5” double amplitude, 2G Peak, 0.5 oct./min., 2 cycles
9-500Hz, 4G pk-pk, 0.5 oct/min., 2 cycles
* Radiated immunity is met when the power supply is tested in a suitable enclosure.
3