Electrical specifications (cont.), General specifications, Feature specifications – GE Industrial Solutions CLP0212 User Manual
Page 3: Clp0212 open frame power supply, Preliminary data sheet, Isolation specifications

GE
Preliminary Data Sheet
CLP0212 Open Frame Power Supply
90 - 264Vac input; 12Vdc output; 200W Output Power
October 11, 2013
©2012 General Electric Corporation. All rights reserved.
Page 3
Electrical Specifications (cont.)
Parameter
Device
Min
Typ
Max
Unit
Maximum Output Capacitance
All
5000
µF
Standby Output Voltage
CLP0212FPXX5Z01A
CLP0212FPEX5Z01A
5
Vdc
CLP0212FPXX3Z01A
3.3
Vdc
Standby Output Current
All
0.25
Adc
Efficiency: V
IN
= 230Vac, 20% load
All except ..Z02A
86.8
%
50% load
All except ..Z02A
91.1
%
100% load
All except ..Z02A
89.5
%
V
IN
= 115Vac, 20% load
All except ..Z02A
89.2
%
50% load
All except ..Z02A
90.3
%
100% load
All except ..Z02A
87.1
%
Holdup Time – V
IN
= 115Vac, 100% load
65W load for CLP0212FPEXZ02A
All except ..Z02A
CLP0212FPEXZ02A
10
45
ms
V
IN
= 230Vac, 100% load
65W load for CLP0212FPEXZ02A
All except ..Z02A
CLP0212FPEXZ02A
10
45
ms
Isolation Specifications
Parameter
Device
Min
Max
Unit
Isolation Voltage – Input to output
All
3000
Vac
Input to safety ground
All
1500
Vac
Outputs to safety ground
All
50
Vac
General Specifications
Parameter
Device
Symbol
Typ.
Unit
Calculated Reliability based on Telcordia SR-332 Issue 2: Method 1 Case
3 (V
IN
=230Vac, I
o
= 16.7A, T
A
= 40ºC, airflow 200LFM, 90% confidence)
All
FIT
MTBF
1,011.9
988,276
10
9
/Hours
Hours
Weight
All
185
6.5
g
oz.
Feature Specifications
Parameter
Device
Min
Typ
Max
Unit
On/Off Signal Interface – signal referenced to GND
Logic Low (Power Supply ON)
Input Low Current
All
7
mA
Input Low Voltage
All
1
V
Logic High (Power Supply OFF)
Input High Current
All
600
µA
Input Voltage
All
5.5
V
Delay from ON/OFF being enabled to start of output voltage rise
All
50
ms
Output Voltage Rise Time (from 10 to 90% of final value)
All
5
ms
Delay from Input being applied to standby output being in regulation
All
12
ms
Delay from Input being applied to all outputs being in regulation
All
30
ms
Output Holdup time (from loss of AC to output being out of regulation)
All
10
ms
Output Overvoltage Protection (for main output currents above 0.1A)
All
13.8
18
Vdc
2
Holdup time is reduced at cold temperatures