12v austin superlynx, 16a: non-isolated dc-dc power modules, Data sheet – GE Industrial Solutions 12V Austin SuperLynx 16A User Manual
Page 9: Characteristic curves, Test configurations, Continued)

GE
Data Sheet
12V Austin SuperLynx
TM
16A: Non-Isolated DC-DC Power Modules
10Vdc –14Vdc input; 0.75Vdc to 5.5Vdc output; 16A Output Current
May 7, 2013
©2013 General Electric Company. All rights reserved.
Page 9
Characteristic Curves
(continued)
The following figures provide thermal derating curves for the Austin SuperLynx
TM
12V SMT modules.
OUT
PUT
CURR
ENT,
Io
(A)
0
2
4
6
8
10
12
14
16
18
20
30
40
50
60
70
80
90
100 LFM
200 LFM
NC
300 LFM
400 LFM
OUT
PUT
CURR
ENT,
Io
(A)
0
2
4
6
8
10
12
14
16
18
20
30
40
50
60
70
80
90
100 LFM
200 LFM
NC
300 LFM
400 LFM
AMBIENT TEMPERATURE, T
A
O
C AMBIENT
TEMPERATURE,
T
A
O
C
Figure 19. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin = 12Vdc, Vo=0.75Vdc).
Figure 22. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin = 12Vdc, Vo=5.0 Vdc).
O
U
TP
UT CURR
ENT,
Io
(A)
0
2
4
6
8
10
12
14
16
18
20
30
40
50
60
70
80
90
100 LFM
200 LFM
NC
300 LFM
400 LFM
AMBIENT TEMPERATURE, T
A
O
C
Figure 20. Derating Output Current versus Local Ambient
Temperature and Airflow (Vin = 12Vdc, Vo=1.8 Vdc).
OUTPUT C
U
RREN
T, Io
(A)
0
2
4
6
8
10
12
14
16
18
20
30
40
50
60
70
80
90
100 LFM
200 LFM
NC
300 LFM
400 LFM
AMBIENT TEMPERATURE, T
A
O
C
Figure 21. Derating Output Current versus Local Ambient
Temperature and Airflow
(Vin = 12Vdc, Vo=3.3 Vdc).
Test Configurations