Data Sheet
July 27, 2011
EQW006 Series, Eight Brick Power Modules: DC-DC Converter
36 – 75Vdc Input; 12Vdc Output; 6A Output Current
LINEAGE
POWER
3
Electrical Specifications
(continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Output Voltage Set-point
All
V
O, set
11.8 12.0 12.2 Vdc
(V
IN
=
IN, min
, I
O
=I
O, max
, T
A
=25°C)
Output Voltage
All
V
O
11.6
12.4 Vdc
(Over all operating input voltage, resistive load, and
temperature conditions until end of life)
Adjustment Range
All V
O
10.8
13.2 Vdc
Selected by external resistor
Output Regulation
Line (V
IN
=V
IN, min
to V
IN, max
) All
0.1 %
V
O, set
Load (I
O
=I
O, min
to I
O, max
) All
0.1 %
V
O, set
Temperature (T
ref
=T
A, min
to T
A, max
) All
0.2
% V
O, set
Output Ripple and Noise on nominal output
measured with 10
F Tantalum, 1F ceramic
(V
IN
=V
IN, nom
,I
O
= I
O, max
, T
A
=T
A, min
to T
A, max
)
RMS (5Hz to 20MHz bandwidth)
All
15 25 mV
rms
Peak-to-Peak (5Hz to 20MHz bandwidth)
All
40 75
mV
pk-pk
External Capacitance
All
C
O, max
0
1000
μF
Output Current
All
I
o
0
6 Adc
Output Current Limit Inception (Hiccup Mode )
All
I
O, lim
7.0
Adc
(V
O
= 90% of V
O, set
)
Output Short-Circuit Current
All I
O, s/c
0.5
Adc
(V
O
≤250mV) ( Hiccup Mode )
Efficiency
V
IN
= V
IN, nom
, T
A
=25°C All
η
91.5
%
I
O
=I
O, max ,
V
O
= V
O,set
Switching Frequency
All
f
sw
300 kHz
Dynamic Load Response
(dIo/dt=0.1A/
s; V
IN
= V
IN, nom
; T
A
=25°C)
Load Change from Io= 50% to 75% of Io,max;
220
F
Tantalum or Electrolytic external capacitance
Peak Deviation
All
V
pk
200
mV
Settling Time (Vo<10% peak deviation)
All t
s
250
s
(
Io/t=0.1A/s; V
in
=V
in
,set; T
A
=25°C)
Load Change from Io= 50% to 25% of Io,max;
220
F Tantalum or Electrolytic external capacitance
Peak Deviation
All
V
pk
200
mV
Settling Time (Vo<10% peak deviation)
All t
s
250
s