Data sheet, Feature specifications – GE Industrial Solutions EBVW020A0B Barracuda Series User Manual
Page 4

GE
Data Sheet
EBVW020A0B Barracuda Series; DC-DC Converter Power Modules
36-75Vdc Input; 12.0Vdc, 20.0A, 240W Output
July 22, 2013
©2012 General Electric Company. All rights reserved.
Page 4
Feature Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Remote On/Off Signal Interface
(V
IN
=V
IN, min
to V
IN, max
, Signal referenced to V
IN-
terminal)
Negative Logic: device code suffix “1”
Logic Low = module On, Logic High = module Off
Positive Logic: No device code suffix required
Logic Low = module Off, Logic High = module On
Logic Low Specification
On/Off Thresholds:
Remote On/Off Current – Logic Low
All
I
on/off
280
310
μA
Logic Low Voltage
All
V
on/off
-0.3
0.8 V
dc
Logic High Voltage – (Typ = Open Collector)
All
V
on/off
2.0
14.5 V
dc
Logic High maximum allowable leakage current
(V
on/off
= 2.0V)
All I
on/off
10
μA
Maximum voltage allowed on On/Off pin
All
V
on/off
14.5 V
dc
Turn-on Delay and Rise Time (I
O
=I
O, max
)
T
delay
=Time until V
O
= 10% of V
O,set
from either application of Vin
with Remote On/Off set to On (Enable with Vin); or operation of
Remote On/Off from Off to On with Vin already applied for at
least 150 milli-seconds (Enable with on/off).
* Increased T
delay
due to startup for parallel modules.
All w/o -P
T
delay, Enable with
Vin
160 ms
All w/o-P
T
delay
,
Enable with
on/off
40 ms
w/ -P
T
delay
,
Enable with
Vin
180* ms
w/ -P
T
delay
,
Enable with
on/off
40* ms
T
rise
=Time for V
O
to rise from 10% to 90% of V
O,set
, For C
O
>5000uF, I
O
must be < 50% I
O, max
during T
rise
.
* Increased T
rise
when Vo exists at startup for parallel
modules.
All w/o -P
T
rise
40 ms
w/ -P
T
rise
300* ms
Load Sharing Current Balance
(difference in output current across all modules with outputs in
parallel, no load to full load)
-P Option
I
diff
3 A
Prebias Output Load Performance:
Back Bias current sunk by output during start-up
Back Bias current sunk by output during shut-down
All
50
50
mA
mA
Remote Sense Range
All w/ ”9”
option
V
Sense
0.5 V
dc
Output Voltage Adjustment range
All w/ ”9”
option
V
O, set
6.0
13.2 V
dc
Output Overvoltage Protection
All
V
O,limit
14.5
17.0 V
dc
Overtemperature Protection
All T
ref
140
°C
(See Feature Descriptions)
Input Undervoltage Lockout
Turn-on Threshold
35 36 V
dc
Turn-off Threshold
32 33.5
V
dc
Input Overvoltage Lockout
Turn-off Threshold
85 86 V
dc
Turn-on Threshold
76 79
V
dc