B.3.41. AT+BTSEC,Authentication,Encryption
Response
OK
Purpose
Set authentication and data encryption
Parameters
Authentication=0: Inactivate (Default)
Authentication=1: Activate
Encryption=0: Inactivate (Default)
Encryption=1: Activate
Description
If the authentication is activated, the pin code must be set by AT+BTKEY command.
Data encryption cannot be used when authentication is not enabled, i.e.
Authentication=0 and Encryption=1 will not work properly.
B.3.42. AT+BTNAME=$string
Response
OK
Purpose
Change device name
Parameters
$string
= New device name (Default=BCD110_v3.0.0-445566)
Description
Parani-BCD110V3 can have a user friendly name for easy identification. The name
allows up to 30 alpha-numeric characters.
Example
AT+BTNAME=My-Parani-BCD
B.3.43. AT+BTLPM,n
Response
OK
Purpose
Set low power mode
Parameters
n=0: Inactivate (Default)
n=1: Activate
Description
During no data transmission, Parani-BCD110V3 can be in low power mode to save the
power. Low Power Timeout is set to S-register S52. So if low power mode is activated
and if there is no data transfer during a period specified in S52, Parani-BCD110V3 will
be entered low power mode.
Please note that it takes a few seconds to make the Parani-BCD110V3 out of low power
mode.
B.3.44. AT&V
Response
S0:m0;S1:m1; …Sn:mn
OK
Purpose
Display all the S-registers
Description
All parameters are stored at S-register in flash memory. These values are sustained
until hardware reset.