B.3.14, B.3.15, B.3.16. at+setesc,nn – SENA Parani-BCD110V3 User Manual
Page 56
Sena Technologies, Inc
56
(n=1 or n=2)
TASK1 OK
TASK2 OK
TASK3 OK
TASK4 OK
TASK5 OK
TASK6 OK
TASK7 OK
Purpose
Set multiple connection mode
Parameters
n=0: Single Connection Mode (Default)
n=1: Multi-Drop Mode
n=2: Node Switching Mode
Description
Set single connection mode, multi-drop mode or node switching mode.
B.3.14. +++
Response
OK
Purpose
Convert the operation status of ‘Connect’ to ‘Standby’
Description
In ‘Connect’ status, data from host is transmitted to the other side Bluetooth device,
and any AT command is not accepted except this command, which is not echoed on
the screen.
When Parani-BCD110V3 encounters a character ‘+’ from host, it stops the data
transmission and waits for next 2 characters. If the next 2 characters are not ‘+’, it
restart to transmit data including the first ‘+’ as well. If so, it converts the operation
status to ‘Standby’.
If the data from host includes ‘+++’, it will convert the operation status to ‘Standby’.
Notice that Parani-BCD110V3 holds data transmission when it encounters ‘+’, until
receiving next character.
‘+’ is an escape sequence character by default, which is changeable by AT+SETESC
and stored at S-register 28.
B.3.15. - - -
Response
OK
Purpose
Convert the operation status of ‘SPP On-line’ to ‘Remote Configuration’
Description
Basic operation of ‘---’ is same as that of ‘+++’. While ‘+++’ converts
‘Connect’ status to ‘Standby’ status, ‘---’ converts ‘Connect’ status to
‘Remote Configuration’ status.
‘-’ is a Remote Escape Sequence character by default, which is changeable
and stored at S-register 71.
B.3.16. AT+SETESC,nn
Response
OK