B.3.31. at+dio, B.3.32. at+aio, B.3.33. at+iops=nn – SENA Parani-BCD110V3 User Manual
Page 62: B.3.34. at+diocds=nn
Sena Technologies, Inc
62
Example
AT+DIO=00011
B.3.31. AT+DIO?
Response
DIO : <00000>
OK
Purpose
Display the current DIO status
Description
The current status of DIO pins can be displayed. When I/O configuration of all the
DIO pins is set as ‘Disabled, response is ‘ERROR’.
B.3.32. AT+AIO?
Response
AIO0 : <1.2123>
AIO1 : <1.0019>
OK
Purpose
Display the current AIO status
Description
The current status of AIO pins can be displayed in voltage. When I/O configuration of
all the AIO pins is set as ‘Disabled, response is ‘ERROR’.
B.3.33. AT+IOPS=nn
Response
OK
Purpose
Set periodic sampling
Parameters
nn =0~3600 (Default 0)
0 Disabled
1~3600 Sampling Period in second
Description
The digital and analog I/O status of Parani-BCD110V3 can be monitored periodically.
This command sets the sampling period in second. Change is applied without
rebooting.
When I/O configuration of all the I/O pins is set as ‘Disabled, the periodic sampling
does not work.
Example
AT+IOPS=0
B.3.34. AT+DIOCDS=nn
Response
OK
Purpose
Set DIO changed detection sampling
Parameters
nn = 0/1 ( Default 0 )