B.3.7. at+btinq, B.3.8. at+btlast, B.3.9. at+btver – SENA Parani-BCD110V3 User Manual
Page 54: B.3.10. at+btrssi,n (single connection mode only)

Sena Technologies, Inc
54
Encrypt=0/1 (Encryption is not activated when 0)
FlowControl=HWFC/NoFC
NN in CONNECT (NN) of Status stands for the type of connection and consists of the
first letter of SPP, I/O and SCO. (ex. SSI -> connections established in SPP, SCO, I/O
profile)
B.3.7. AT+BTINQ?
Response
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
112233445566,FriendlyName,CoD
OK
Purpose
Search Bluetooth devices nearby
Description
The Bluetooth devices in Inquiry scan mode nearby are displayed with their BD
addresses, Device names, and Class of device.
Maximum 15 devices are scanned for 30 seconds. (Default 30 seconds in S-register
33 and default 15 value in S-register 24)
B.3.8. AT+BTLAST?
Response
112233445566
Purpose
Display the BD address of the last connected device
Description
The Bluetooth device last connected to this Parani-BCD110V3 is displayed with its
BD address.
B.3.9. AT+BTVER?
Response
BCD110_v3.0.0
OK
Purpose
Display device firmware version
Description
Display device firmware version
B.3.10. AT+BTRSSI,n (Single Connection Mode Only)
Response
OK
0,255,0,0 (repeatedly) (0, LinkQuality, 0, RSSI)
Purpose
Test signal strength
Parameters
n=0: Stop signal strength test
n=1: Start signal strength test
Description
When Bluetooth connection is established, you can use this command in Standby
status. The signal strength will be displayed repeatedly in order of Status, LinkQuality,