B.3.17. ato (atox, atobdaddr), B.3.18. at+btcancel, B.3.19. at+btscan – SENA Parani-BCD110V3 User Manual
Page 57: B.3.20. at+btscan,n,to

Sena Technologies, Inc
57
Purpose
Change the escape sequence character
Description
Escape sequence character set to ‘+’ by default is changeable.
The parameter nn must be a printable character.
Example
AT+SETESC,+
OK
B.3.17. ATO (ATOx, ATObdaddr)
Response
None
Purpose
Convert the operation status of ‘Standby’ to ‘Connect’
Description
You can convert the operation status of ‘Standby’ to ‘Connect’ ready to transmit data.
In Node Switching mode, a specific slave can be specified to become an active
connection by specifying the connection number or the Bluetooth address.
Example
ATO
ATO4
ATO000195000001
B.3.18. AT+BTCANCEL
Response
OK
Purpose
Terminate the current executing task
Description
This terminates a current executing task, such as Inquiry scan and Page scan, then
converts the operation status to ‘Standby’.
B.3.19. AT+BTSCAN
Response
OK
CONNECT 112233445566
Purpose
Wait for inquiry and connection from other Bluetooth devices
Description
This allows the inquiry and connection from the other Bluetooth devices. The operation
status will be in ‘Pending’ after this command. When connection is made and released,
the operation status is back to ‘Pending’. To convert the operation status to ‘Standby’
AT+BTCANCEL must be used.
This has the same effect as AT+BTSCAN,3,0.
When connection is made with other Bluetooth device, response will be ‘CONNECT’
with its BD address.
B.3.20. AT+BTSCAN,n,to
Response
OK
CONNECT 112233445566