ProBee-ZE20S User Guide Rev.1.10
device to poll more rapidly for a short time when receiving RF data.
Execute
ATS56?
ATS56=
Response
OK
OK
Default
5
Range
0 - 10000
9.6
Sink
9.6.1
S61
Description
Get/Set the sink node and the sink advertise period in seconds. When a node is
defined as a sink, it can multicast its address to the rest of the network in this period. If
set to 0, sink advertise is disabled.
Execute
ATS61?
ATS61=
Response
OK
OK
Default
0
Range
0 – 10000
9.6.2
S62
Description
Get/Set the period to send Many-to-One Route Request. Many-to-One Route Request
(MTOR) creates routes from every node in the network back to this node. It is useful
when this node acts as a sink node.
Execute
ATS62?
ATS62=
Response
OK
OK
Default
0
Range
0 – 10000
9.7
Frequency Agility
9.7.1
S71
Description
Get/Set the Frequency agility function. If it is enabled in coordinator mode, node will
automatically shift operating channel to one of channel masks when its unicasts fail
more than threshold.
Execute
ATS71?
ATS71=
Response
OK
OK
Default
0
Range
0 – 1