SENA ProBee-ZE20S User Manual
Page 85

85
ProBee-ZE20S User Guide Rev.1.10
9.2
Network Settings
9.2.1
S21
Description
Get/Set the inter character timeout in milliseconds. It determines to send data packet
after this time.
Execute
ATS21?
ATS21=
Response
OK
OK
Default
100
Range
0 - 10000
9.2.2
S22
Description
Get/Set the timeout to permit joining. It determines the time in seconds that the device
will allow other devices to join to it when it starts network but an end-device cannot
perform it. If set to 255, the device will always permit joining.
Execute
ATS22?
ATS22=
Response
OK
OK
Default
255
Range
0 - 255
9.2.3
S23
Description
Get/Set the power boost mode of the module. If enabled, boost mode improves
sensitivity and increases output power, improving the link margin and range.
Execute
ATS23?
ATS23=
Response
OK
OK
Default
0
Range
0 – 1
9.3
Data Transmissions
9.3.1
S31
Description
Get/Set the application-ACK mode. If it is enabled, a sender node retransmits data
packet when it fails to receive ACK from receiver node. This value must be set same
on the source and destination node for data transmission.
Execute
ATS31?
ATS31=
Response
OK
OK
Default
1
Range
0 - 1