SENA ProBee-ZE20S User Manual
Page 46

46
ProBee-ZE20S User Guide Rev.1.10
To get/set the I/O values of the remote devices, remote AT commands can be used as below.
AT+REMOTE=
Example)
AT+REMOTE=00019500000F3BA1,AT+DIO?
10001000111**0000
OK
5.2.2
Periodic Sampling
The ZE20S can be configured to send its I/O status to a remote device at a periodic rate. To configure this
way, please use the AT commands below:
AT+DESTLA=
, where
node.
ATS42=
, where
ATS43=
, where
If set to is 1, the sink node is set as the monitoring node.
A device can be a sink node by setting S-register 61.The sink node multicasts its address to the other
devices in the destination group in the network according to the value of S-register 61, which is called
advertising.
ATZ
Reset the device to apply the changes
The ZE20S can be configured to display periodic sampling data coming from the other nodes. To enable
this feature, please use the AT command below:
ATS11=
, where
display incoming message in command mode, S11 should be enabled.
If this feature is enabled, incoming message will display in the form of: