SENA ProBee-ZE20S User Manual
Page 81

81
ProBee-ZE20S User Guide Rev.1.10
AT+LINKKEY=5A46…21
# set the 128-bit trust center link key (5A46…21)
ATZ
# Apply the change
OK
# Response
AT+NWKKEY=0
# set the 128-bit network key (random key)
OK
# Response
AT+UPDATEKEY
# update the changed network key
OK
# Response
8.4
UART Settings
AT+BAUDRATE=115200
# set baud rate (115,200bps)
OK
# Response
AT+DATABIT=8
# set data bit (8bit)
OK
# Response
AT+PARITY=0
# set parity (none)
OK
# Response
AT+STOPBIT=1
# set stop bit (1bit)
OK
# Response
AT+FLOWCTRL=2
# set flow control (hardware)
OK
# Response
ATZ
# Apply the change
OK
# Response
8.5
GPIO
AT+GPIO=55003300000441122
OK
# Response
ATZ
# Apply the change
OK
# Response
AT+GPIO0
# check the current GPIO status (GPIO0)
5
OK
# Response
AT+DIO
# check the current DIO value
10000000000**0011
OK
# Response
AT+AI
# check the current AI value
****,****,1786,23A2,****,****
OK
# Response