beautypg.com

SENA ProBee-ZE10 User Manual

Page 89

background image

89

ProBee-ZE10 User Guide Rev.1.5

node according to GPIO monitoring node (S43). If set to 0, GPIO change detection

sampling is disabled.

Execute

ATS44?

ATS44=

Response

OK

OK

Default

0

Range

0 – 1

9.4.5

S45

Description

Get/Set the GPIO remote control mode. If any GPIO pin is set to digital input, a node

can control the I/O status of a remote node if the I/O pin of the remote node is set to

digital output. It is possible to use when GPIO monitoring is enabled (GPIO monitoring

period, S42 > 0) or GPIO change detection sampling is enabled.(GPIO change

detection sampling mode, S44 = 1)

Execute

ATS45?

ATS45=

Response

OK

OK

Default

0

Range

0 – 1

9.5

End-Device

9.5.1

S51

Description

Get/Set the poll timeout for a parent node in seconds. If an end-device or a sleepy

end-device does not send a poll request to its parent coordinator or router within the

poll timeout, the end-device is removed from the child table.

Execute

ATS51?

ATS51=

Response

OK

OK

Default

60

Range

0 – 4177920

9.5.2

S52

Description

Get/Set the sleepy end-device poll period in milliseconds. Adaptive polling may allow

the sleepy end-device to poll more rapidly for a short time when receiving RF data.

Execute

ATS52?

ATS52=

Response

OK

OK

Default

100

Range

0 - 10000