beautypg.com

SENA ProBee-ZE10 User Manual

Page 85

background image

85

ProBee-ZE10 User Guide Rev.1.5

Response

OK

OK

Default

100

Range

0 - 10000

9.2.2

S22

Description

Get/Set the timeout to permit joining. It determines the time in seconds that the device

will allow other devices to join to it when it starts network but an end-device cannot

perform it. If set to 255, the device will always permit joining.

Execute

ATS22?

ATS22=

Response

OK

OK

Default

255

Range

0 - 255

9.2.3

S23

Description

Get/Set the power boost mode of the module. If enabled, boost mode improves

sensitivity by 1dB and increases output power by 2dB, improving the link margin and

range.

Execute

ATS23?

ATS23=

Response

OK

OK

Default

0

Range

0 – 1

9.3

Data Transmissions

9.3.1

S31

Description

Get/Set the application-ACK mode. If it is enabled, a sender node retransmits data

packet when it fails to receive ACK from receiver node. This value must be set same

on the source and destination node for data transmission.

Execute

ATS31?

ATS31=

Response

OK

OK

Default

1

Range

0 - 1

9.3.2

S32

Description

Get/Set the transmission retries. A sender tries to retransmit up to this value when

transmission fails. (CAUTION: It is recommended to set the smallest value that the