SENA ProBee-ZE10 User Manual
Page 69
69
ProBee-ZE10 User Guide Rev.1.5
7.4.6
AT+STACK or AT+ZS
Description
Get/Set the ZigBee stack profile value. This value must be set the same on all devices
that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro)
Execute
AT+STACK?
AT+STACK=
Response
OK
OK
Default
0
Range
0 - 2
7.4.7
AT+NODENAME or AT+NN
Description
Get/Set the node name. It can be used to make a clear distinction role or functionality
of local node from others.
Execute
AT+NODENAME?
AT+NODENAME=
Response
OK
OK
Default
ProBee-ZE
Range
Up to 16 characters
7.5
Network Formation and Join
7.5.1
AT+ASCAN or AT+AS
Description
Perform a scanning for existing network. It can take up to 5 seconds. (CAUTION: It is
possible to cause a link error if a node is a parent of an end-device.)
Execute
AT+ASCAN
AT+ASCAN=
Response
List of the existing networks …
OK
7.5.2
AT+ESCAN or AT+ES
Description
Perform a scanning for energy level of all channels. It can be used to avoid
interference. It can take up to 5 seconds. The RSSI energy level ranges from
approximately -100 to +127 in dBm at PTv1.4 or later. It is the real RSSI value plus an
offset of +154 at PTv1.3 or earlier. (CAUTION: It is possible to cause a link error if a
node is a parent of an end-device.)
Execute
AT+ESCAN
AT+ESCAN=
Response
List of the RSSI for each channel …
OK