beautypg.com

SENA ProBee-ZE10 User Manual

Page 69

background image

69

ProBee-ZE10 User Guide Rev.1.5

7.4.6

AT+STACK or AT+ZS

Description

Get/Set the ZigBee stack profile value. This value must be set the same on all devices

that should join the same network. (0: Network specific, 1: ZigBee, 2: ZigBee Pro)

Execute

AT+STACK?

AT+STACK=

Response

OK

OK or ERROR

Default

0

Range

0 - 2

7.4.7

AT+NODENAME or AT+NN

Description

Get/Set the node name. It can be used to make a clear distinction role or functionality

of local node from others.

Execute

AT+NODENAME?

AT+NODENAME=

Response

OK

OK or ERROR

Default

ProBee-ZE

Range

Up to 16 characters

7.5

Network Formation and Join

7.5.1

AT+ASCAN or AT+AS

Description

Perform a scanning for existing network. It can take up to 5 seconds. (CAUTION: It is

possible to cause a link error if a node is a parent of an end-device.)

Execute

AT+ASCAN

AT+ASCAN=

Response

||||

List of the existing networks

OK

7.5.2

AT+ESCAN or AT+ES

Description

Perform a scanning for energy level of all channels. It can be used to avoid

interference. It can take up to 5 seconds. The RSSI energy level ranges from

approximately -100 to +127 in dBm at PTv1.4 or later. It is the real RSSI value plus an

offset of +154 at PTv1.3 or earlier. (CAUTION: It is possible to cause a link error if a

node is a parent of an end-device.)

Execute

AT+ESCAN

AT+ESCAN=

Response

|

List of the RSSI for each channel

OK