7.5.6

AT+PERMIT or AT+PJ

Description

Permit other nodes to join the network. (0~254s, 255=continuance) An end-device

cannot perform it.

Execute

AT+PERMIT

AT+PERMIT=

Response

OK

Range

0 - 255

7.5.7

AT+LEAVE or AT+LV

Description

Leave the current network.

Execute

AT+LEAVE

Response

OK

7.6

End-device

7.6.1

AT+SLEEP or AT+SM

Description

Enter the sleep mode immediately if the node is a sleepy end-device.

Execute

AT+SLEEP

Response

OK

7.6.2

AT+PARENTLA or AT+PL

Description

Get the 64-bit IEEE address of the parent node.

Execute

AT+PARENTLA?

Response

OK

7.6.3

AT+PARENTSA or AT+PS

Description

Get the 16-bit Node ID of the parent node.

Execute

AT+PARENTSA?

Response

OK

7.6.4

AT+CHILDTABLE or AT+CT

Description

Get the child table composed of the end-devices.

Execute

AT+CHILDTABLE?

Response

||

List of the child nodes

OK